• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2017.tde-05102017-091731
Document
Author
Full name
Henrique Takachi Moriya
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1999
Supervisor
Committee
Moraes, Jose Carlos Teixeira de Barros (President)
Cestari, Idágene Aparecida
Negrão, Carlos Eduardo
Title in Portuguese
Avaliação de transdutores para análise metabólica humana.
Keywords in Portuguese
Análise metabólica humana
Bioengenharia
Dióxido de carbono
Instrumentação biomédica
Oxigênio
Sistema respiratório
Transdutores fluxo
Abstract in Portuguese
A calorimetria indireta para análise do metabolismo humano tem se mostrado um método não invasivo de crescente importância no estudo mais preciso das respostas metabólicas e cardio-respiratórias. Entretanto, o alto custo dos equipamentos aliado à falta de conhecimento das técnicas tem impedido a disseminação do uso de analisadores metabólicos no Brasil. Este trabalho foi desenvolvido com o intuito de oferecer uma visão global dos procedimentos de calorimetria indireta aplicados à avaliação do metabolismo humano sob a abordagem de Engenharia Biomédica. Foram avaliados três transdutores tipicamente utilizados em equipamentos de calorimetria indireta para análise metabólica humana: um transdutor eletroquímico de oxigênio, um transdutor de dióxido de carbono por radiação infravermelha e um transdutor de fluxo em volume tipo turbina. O transdutor de oxigênio mostrou-se bastante confiável, mas com um tempo de resposta bastante elevado para aplicações em análises de respiração a respiração. A principal deficiência do transdutor de dióxido de carbono está no fato de sua configuração proporcionar um aumento significativo na resistência à respiração do indivíduo. Verificou-se que o transdutor de fluxo em volume apresenta um melhor comportamento para um fluxo em torno de 20 litros/minuto. Apesar das limitações apresentadas pelos transdutores, os resultados dos ensaios foram úteis e representativos para a compreensão do funcionamento de um analisador metabólico humano porcalorimetria indireta, evidenciando quais deficiências devem ser sanadas em pesquisas futuras e os cuidados a serem considerados na implantação do laboratório para análise metabólica/respiratória sendo instalado no Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
Title in English
Assessment of transducers to human metabolic analysis.
Keywords in English
Biomedical instrumentation
Carbon dioxide
Flow
Human metabolic analysis
Oxygen
Transducers
Abstract in English
The indirect calorimetry for analysis of the human metabolism has been a no invasive method of increasing importance in the study of metabolic and cardiorespiratory responses. However, the high cost of the equipment ally to the lack of knowledge of the techniques have been obstacles to the use of metabolic analysers in Brazil. This research was developed with the intention to offer a global vision of the applied procedures of indirect calorimetry to the evaluation of the human metabolism under the prism of the Biomedical Engineering. Three transducers typically used in equipment of indirect calorimetry for metabolic analysis had been evaluated: an electrochemical transducer of oxygen, a carbon dioxide transducer by infrared absorption and a turbine flowmeter. The oxygen transducer revealed sufficiently trustworthy, but a too high response time for applications in breath by breath analyses. The main deficiency of the transducer of carbon dioxide is to provide a significant increase in the flow resistance. It was verified that the flowmeter presents one better behavior for a stream around 20 litres/minute. Despite the limitations presented for the transducers, the results of the assays had been useful and representative for the understanding of the functioning of a human metabolic analyser for indirect calorimetry, evidencing which points have to be improved in future researches and to be considered in the implantation of the laboratory for metabolic and respiratory analysis being installed in the Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-10-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.