• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.3.2016.tde-04012016-172513
Documento
Autor
Nome completo
Cecília Romaro
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2015
Orientador
Banca examinadora
Itiki, Cinthia (Presidente)
Cordero, Arturo Forner
Teixeira, Luis Augusto
Título em português
Variação da ordem ótima de modelo autorregressivo com a força de contração muscular e a duração do eletromiograma.
Palavras-chave em português
Bioengenharia
Contração muscular
Eletromiografia de agulha
Modelo autorregressivo
Sistema linear invariante no tempo (SLIT)
Resumo em português
Os sinais de eletromiografia de agulha podem ser modelados por um sistema linear invariante no tempo (SLIT). A pergunta é: Quantos coeficientes são necessários para tal? O presente mestrado estuda, para sinais de eletromiografia de agulha gravados sob as mesmas condições experimentais, como varia o número ótimo de coeficientes autorregressivos com o comprimento das épocas e com a força de contração muscular concomitantemente. O estudo foi realizado tendo como base sinais de 10%, 25%, 50% e 80% da máxima contração voluntária (MCV) e tendo épocas de 500ms, 250ms, 100ms, 50ms e 25ms de seis indivíduos normais. Desta forma, uma função densidade de probabilidade é sugerida para a ordem do modelo autorregressivo que melhor descreva o sinal de eletromiografia obtido a uma força de contração específica e que tenha uma duração de época definida.
Título em inglês
Variation of optimal autoregressive order with electromyogram length and contraction force
Palavras-chave em inglês
Autoregressive model
Linear time-invariant system
Muscle contraction
Needle electromyography
Resumo em inglês
Needle electromyography signals (EMG) can be modeled by a linear time invariant system (LTI). The posed question is How many coefficients are needed for an adequate modeling? This Masters dissertation studies how the optimal number of autoregressive coefficients changes concomitantly with the epoch length and the muscle contraction force for needle electromyography signals recorded under the same experimental conditions. The study was conducted on signals from six normal individuals at 10%, 25%, 50% and 80% of the maximum voluntary contraction and epoch lengths of 500ms, 250ms, 100ms, 50ms and 25ms. Thus, a probability density function is suggested for the autoregressive model order that best describes the electromyographic signal obtained at a specific "contraction force" and has a defined "epoch length".
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2016-01-14
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • ROMARO, C, e ITIKI, Cinthia. Variação da ordem autorregressiva com a força de contração muscular e a duração do eletromiograma. In XXIV Congresso Brasileiro de Engenharia Biomédica, Uberlândia, 2014. Anais do XXIV Congresso Brasileiro de Engenharia Biomédica., 2014.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.