• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2016.tde-04012016-172513
Document
Auteur
Nom complet
Cecília Romaro
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Itiki, Cinthia (Président)
Cordero, Arturo Forner
Teixeira, Luis Augusto
Titre en portugais
Variação da ordem ótima de modelo autorregressivo com a força de contração muscular e a duração do eletromiograma.
Mots-clés en portugais
Bioengenharia
Contração muscular
Eletromiografia de agulha
Modelo autorregressivo
Sistema linear invariante no tempo (SLIT)
Resumé en portugais
Os sinais de eletromiografia de agulha podem ser modelados por um sistema linear invariante no tempo (SLIT). A pergunta é: Quantos coeficientes são necessários para tal? O presente mestrado estuda, para sinais de eletromiografia de agulha gravados sob as mesmas condições experimentais, como varia o número ótimo de coeficientes autorregressivos com o comprimento das épocas e com a força de contração muscular concomitantemente. O estudo foi realizado tendo como base sinais de 10%, 25%, 50% e 80% da máxima contração voluntária (MCV) e tendo épocas de 500ms, 250ms, 100ms, 50ms e 25ms de seis indivíduos normais. Desta forma, uma função densidade de probabilidade é sugerida para a ordem do modelo autorregressivo que melhor descreva o sinal de eletromiografia obtido a uma força de contração específica e que tenha uma duração de época definida.
Titre en anglais
Variation of optimal autoregressive order with electromyogram length and contraction force
Mots-clés en anglais
Autoregressive model
Linear time-invariant system
Muscle contraction
Needle electromyography
Resumé en anglais
Needle electromyography signals (EMG) can be modeled by a linear time invariant system (LTI). The posed question is How many coefficients are needed for an adequate modeling? This Masters dissertation studies how the optimal number of autoregressive coefficients changes concomitantly with the epoch length and the muscle contraction force for needle electromyography signals recorded under the same experimental conditions. The study was conducted on signals from six normal individuals at 10%, 25%, 50% and 80% of the maximum voluntary contraction and epoch lengths of 500ms, 250ms, 100ms, 50ms and 25ms. Thus, a probability density function is suggested for the autoregressive model order that best describes the electromyographic signal obtained at a specific "contraction force" and has a defined "epoch length".
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-01-14
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • ROMARO, C, e ITIKI, Cinthia. Variação da ordem autorregressiva com a força de contração muscular e a duração do eletromiograma. In XXIV Congresso Brasileiro de Engenharia Biomédica, Uberlândia, 2014. Anais do XXIV Congresso Brasileiro de Engenharia Biomédica., 2014.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.