• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2016.tde-04012016-172513
Document
Author
Full name
Cecília Romaro
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Itiki, Cinthia (President)
Cordero, Arturo Forner
Teixeira, Luis Augusto
Title in Portuguese
Variação da ordem ótima de modelo autorregressivo com a força de contração muscular e a duração do eletromiograma.
Keywords in Portuguese
Bioengenharia
Contração muscular
Eletromiografia de agulha
Modelo autorregressivo
Sistema linear invariante no tempo (SLIT)
Abstract in Portuguese
Os sinais de eletromiografia de agulha podem ser modelados por um sistema linear invariante no tempo (SLIT). A pergunta é: Quantos coeficientes são necessários para tal? O presente mestrado estuda, para sinais de eletromiografia de agulha gravados sob as mesmas condições experimentais, como varia o número ótimo de coeficientes autorregressivos com o comprimento das épocas e com a força de contração muscular concomitantemente. O estudo foi realizado tendo como base sinais de 10%, 25%, 50% e 80% da máxima contração voluntária (MCV) e tendo épocas de 500ms, 250ms, 100ms, 50ms e 25ms de seis indivíduos normais. Desta forma, uma função densidade de probabilidade é sugerida para a ordem do modelo autorregressivo que melhor descreva o sinal de eletromiografia obtido a uma força de contração específica e que tenha uma duração de época definida.
Title in English
Variation of optimal autoregressive order with electromyogram length and contraction force
Keywords in English
Autoregressive model
Linear time-invariant system
Muscle contraction
Needle electromyography
Abstract in English
Needle electromyography signals (EMG) can be modeled by a linear time invariant system (LTI). The posed question is How many coefficients are needed for an adequate modeling? This Masters dissertation studies how the optimal number of autoregressive coefficients changes concomitantly with the epoch length and the muscle contraction force for needle electromyography signals recorded under the same experimental conditions. The study was conducted on signals from six normal individuals at 10%, 25%, 50% and 80% of the maximum voluntary contraction and epoch lengths of 500ms, 250ms, 100ms, 50ms and 25ms. Thus, a probability density function is suggested for the autoregressive model order that best describes the electromyographic signal obtained at a specific "contraction force" and has a defined "epoch length".
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-01-14
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • ROMARO, C, e ITIKI, Cinthia. Variação da ordem autorregressiva com a força de contração muscular e a duração do eletromiograma. In XXIV Congresso Brasileiro de Engenharia Biomédica, Uberlândia, 2014. Anais do XXIV Congresso Brasileiro de Engenharia Biomédica., 2014.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.