Título en portugués
Arquitetura ODP-CIM aplicada na previsão distribuída da carga do sistema elétrico de potência.
Palabras clave en portugués
arquitetura de software
modelagem de dados
sistemas de informação
sistemas distribuidos
sistemas elétricos de potência
Resumen en portugués
O presente trabalho apresenta a utilização do modelo CIM – Common Information Model com uma abordagem ODP – Open and Distributed Processing na definição de uma arquitetura distribuída. A modelagem ODP-CIM efetuada busca validar formalmente a escolha da WBEM – Web Based Enterprise Management como arquitetura distribuída responsável pela interoperabilidade entre sistemas heterogêneos de uma empresa de energia elétrica. O contexto WBEM adicionalmente inclui a modelagem CIM das informações, de modo que o ambiente resultante pode ser visto como uma coleção distribuída de sistemas inter-relacionados. De modo a se verificar a adequação da WBEM como provedora de interoperabilidade e distribuição, será implementado um protótipo; o SISDEC - Sistema Distribuído de Estudo de Carga, responsável pela previsão, através de técnicas de inteligência artificial, da carga nodal de curto prazo do sistema elétrico de potência. A implementação dos modelos resultantes é apresentada assim como os resultados dos testes. Enfocando a disponibilidade aos vários domínios de gestão, das informações modeladas, validando a eficácia da modelagem e a adequação da arquitetura distribuída proposta. Não se visa aqui a apresentação ou definição de métricas específicas, sendo os resultados apresentados do tipo qualitativo. O SISDEC se insere em uma arquitetura de informação corporativa e utilizará um middleware, originário de um projeto de P&D (Pesquisa e Desenvolvimento), como acesso à massa de dados históricos da carga nodal do sistema elétrico de potência, obtidos a partir de um sistema SCADA - Supervisory Control And Data Acquisition. O acesso corporativo às informações processadas pelo SISDEC é efetuado através da intranet da empresa.
Título en inglés
ODP-CIM architecture applied to distributed load forecasting on eletric power system.
Palabras clave en inglés
data models
distributed systems
eletric power systems
information systems
software architecture
Resumen en inglés
The work presents the use of model CIM - Common Information Model with a boarding ODP - Open and distributed Processing in the definition of a distributed architecture. Effected modeling ODP-CIM search to validate formally the choice of the WBEM - Web Based Enterprise Management as architecture distributed responsible for the interoperation between heterogeneous systems in a company of electric energy. The contest of WBEM additionally includes modeling CIM of the information, in way that the resultant environment can be seen as a distributed collection of interrelated systems. In order to verify the adequacy of the WBEM as supplier of the interoperation and distribution, an archetype will be implemented; the SISDEC - Distributed System of Load Study, responsible for the forecast through techniques of artificial intelligence, of the nodal load of short term of the electrical system of power. The implementation of the resultant models is presented, as well as the results of the tests focusing the availability to the some management dominion, of the shaped information, validating the effectiveness of the modeling and the adequacy of the proposed distributed architecture. The metric presentation or definition specific is not aimed here, as the presented results qualitative type. The SISDEC inserts in an architecture of corporative information and it will use one middleware, originated of a R&D project (Research and Development), as access to a mass of nodal load historical data of the electrical system of power, gotten from a system SCADA - Supervisory Control and Date Acquisition. The corporative access to processed information from SISDEC is effected through the Intranet of the company.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2006-09-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.