Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2007.tde-20072009-180319
Document
Author
Full name
Leonardo Zane Vilhegas
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Mansano, Ronaldo Domingues (President)
Gonçalves Neto, Luiz
Moriya, Henrique Takachi
Title in Portuguese
Desenvolvimento de um protótipo para monitoração de saturação de oxigênio e freqüência cardíaca para roedores.
Keywords in Portuguese
Dispositivos e instrumentos médicos
Sensores biomédicós
Sensores ópticos
Sinais biomédicos
Abstract in Portuguese
A utilização de equipamentos para monitoração de parâmetros fisiológicos não é apenas crucial em pacientes que são submetidos a alguns procedimentos médicos, mas é também de extremo valor para animais em uso similar. Este projeto tem como principal objetivo o desenvolvimento de um sistema de monitoração de saturação de oxigênio e freqüência cardíaca para roedores; tal sistema é composto por um dispositivo protótipo compacto e sensor óptico. No presente trabalho, foram utilizadas as tecnologias dos microcontroladores da Microchip para realizar as diversas digitalizações; a tecnologia USB, para realizar a comunicação com computadores e o desenvolvimento da interface desenvolvida com o software disponível da National Instruments, o LabVIEW. Neste estudo, o sistema desenvolvido foi empregado em camundongos e foram realizadas diversas avaliações em laboratório e em campo para a validação do dispositivo protótipo. Os batimentos cardíacos e a saturação de oxigênio, tanto em repouso quanto em movimento, foram detectados pelo protótipo. Os valores de freqüência cardíaca variaram entre 545 e 700 bpm enquanto os valores de saturação de oxigênio variaram entre 80 a 95%.
Title in English
Development of a oxigen saturation and cardiac frequency prototype for rodents.
Keywords in English
Cardiac frequency
Compact
Pulse oximeter
Rodents
Signals process
SpO2
Abstract in English
The equipments use to monitoring physiological parameters isnt just crucial in patients who are submitted to some medical procedures but it is also of extreme value for animals in similar use. This project has as main objective the development of a monitor oxygen saturation and cardiac frequency for mice; the system is compound of a compact prototype device and optic sensor. In the present work, the Microchip microcontrollers technologies had been used, to realize many digitalization; the USB technology interface, to realize the communication with computers and the interface development developed with the available National Instruments software, the LabVIEW. In this study, the developed system was used in mice and have been realized many evaluations in laboratory and field for the prototype validation device. The cardiac beatings and oxygen saturation, as much in rest how in movement they had been detected by the prototype. The values of heart rate had varied of 545 to 700 while the values of oxygen saturation had varied of 80 to 95%.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Abstract.pdf (8.88 Kbytes)
Capa.pdf (12.87 Kbytes)
Resumo.pdf (11.72 Kbytes)
Publishing Date
2009-07-21
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • VILHEGAS, L. Z., et al. Development of transmissible photopletysmography prototype sensor using polimeric fiber optic. AIP Conference Proceedings, 2008, vol. 992, p. 648-652.
  • VILHEGAS, L. Z., et al. Development of transmissible photopletysmography prototype sensor using polymeric fiber optic. In RIAO/OPTILAS 2007, Campinas, 2007. AIP COnference Proceedings., 2007.
  • VILHEGAS, L. Z., e MANSANO, R. D. Desenvolvimento de oximetria de pulso compacta. In XXX Encontro Nacional de Física da Matéria Condensada, São Lourenço, 2007. XXX Encontro Nacional de Física da Matéria Condensada., 2007. Resumo.
  • VILHEGAS, L. Z., e MANSANO, R. D. Oximetro não invasivo para aplicações aeronáuticas. In 3˚ Workshop em Nanotecnologia Aeroespacial, 2007. 3˚ Workshop em Nanotecnologia Aeroespacial., 2007. Resumo.
  • VILHEGAS, L. Z., MOREIRA, A. J., and MANSANO, R. D. Compact pulse oximeter using PIC18F4550 microcontroler. In 1st International Conference on Biomedical Electronics and Devices, Biodevices 2008; Conference Proceeding, 2008. 1st International Conference on Biomedical Electronics and Devices, Biodevices 2008; Conference Proceeding., 2008.
  • MOREIRA, A. J., et al. Study of oxygen plasma for application in sterilization process. In 1st International Conference on Biomedical Electronics and Devices, Biodevices 2008; Conference Proceeding, 2008. 1st International Conference on Biomedical Electronics and Devices, Biodevices 2008; Conference Proceeding., 2008.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.