Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2014.tde-19032015-171810
Documento
Autor
Nombre completo
Deivid Efrain Tellez Porras
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Rodriguez, Edgar Charry (Presidente)
Ferreira, Ademar
Muñoz, Rodrigo Reina
Título en portugués
Desenvolvimento de transmissores de pressão com sensor piezoresistivo e protocolo de comunicação HART.
Palabras clave en portugués
Comunicação digital
Dispositivos eletrônicos
Microeletrônica
Sensor
Resumen en portugués
O presente trabalho é uma pesquisa tecnológica (P&D) de inovação tecnológica de produto para o mercado brasileiro, que visa desenvolver um transmissor de pressão inteligente de alta exatidão com protocolo HART e sensor piezoresistivo em parceria LSI-USP / MEMS Ltda. Fornecendo assim um protótipo de um produto competitivo no mercado brasileiro. Neste trabalho se apresenta uma arquitetura baseada nos transmissores 4-20 mA de alta exatidão da MEMS Ltda. Essa arquitetura mantém as características de desemprenho da medição analógica e adiciona os componentes necessários para suportar as funções do padrão HART com camada física Bell 202. Além da arquitetura, neste documento é apresentado: o desenvolvimento das interfaces entre o algoritmo de compensação e os algoritmos responsáveis da comunicação digital, as modificações no circuito de controle da corrente de laço para permitir a modulação do sinal de 1200 Hz e 2200 Hz usado pela comunicação digital, e o projeto de alimentação do transmissor, que foi projetado visando a eficiência para respeitar os limites de consumo de corrente. Os resultados obtidos com essa nova arquitetura, apresentam que são mantidas as características dos transmissores 4-20 mA usados como base, e que a medição digital tem um nível de erro 0,05 %FS (porcentagem de fundo de escala) menor do que a saída analógica do mesmo transmissor, valor considerável comparado com o 0,2 %FS que é o nível de erro total do sistema. Os protótipos usados para as medições foram caracterizados num processo que levou 35 dias de operação continua, validando assim o projeto elétrico e software desenvolvido.
Título en inglés
Development of a piezoresistive pressure transmitters with hart communication protocol.
Palabras clave en inglés
Digital communication
Electronic devices
Microelectronics
Sensor
Resumen en inglés
This thesis consists of a technical research (P&D) on technological innovations of a highly accurate intelligent pressure transmitter using a HART protocol and piezoresistive sensors in collaboration with LSI-USP / MEMS Ltda. The outcome consists of a prototype of a competitive product in the Brazilian market. This project presents a product architecture based on highly accurate 4-20mA MEMS Ltda. transmitters. It maintains the features necessary for analogical measurements and adds components, which are compatible with the functions of HART with a Bell 202 physical layer. In addition to the architecture, this document presents the development of: interfaces between the compensation algorithm and digital communication algorithms, modifications of the current loop control circuit to allow signal modulation used by digital communications of 1200Hz and 2000Hz, a voltage source project, which envisioned efficiency and considered the limits of current consumption. Results of this architecture show that the 4-20mA transmitter´s characteristics, used as a starting point for the product, are maintained and that digital measurements present 0.05%FS (Full Scale) less error than analogical measurements taken by the same transmitter. This presents a significant error reduction when compared to the total error of the system, which is 0, 2 %FS. The prototypes used for measurements were tested during 35 continuous days, validating their electrical installation and software.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-03-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.