• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2014.tde-19032015-171810
Document
Author
Full name
Deivid Efrain Tellez Porras
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Rodriguez, Edgar Charry (President)
Ferreira, Ademar
Muñoz, Rodrigo Reina
Title in Portuguese
Desenvolvimento de transmissores de pressão com sensor piezoresistivo e protocolo de comunicação HART.
Keywords in Portuguese
Comunicação digital
Dispositivos eletrônicos
Microeletrônica
Sensor
Abstract in Portuguese
O presente trabalho é uma pesquisa tecnológica (P&D) de inovação tecnológica de produto para o mercado brasileiro, que visa desenvolver um transmissor de pressão inteligente de alta exatidão com protocolo HART e sensor piezoresistivo em parceria LSI-USP / MEMS Ltda. Fornecendo assim um protótipo de um produto competitivo no mercado brasileiro. Neste trabalho se apresenta uma arquitetura baseada nos transmissores 4-20 mA de alta exatidão da MEMS Ltda. Essa arquitetura mantém as características de desemprenho da medição analógica e adiciona os componentes necessários para suportar as funções do padrão HART com camada física Bell 202. Além da arquitetura, neste documento é apresentado: o desenvolvimento das interfaces entre o algoritmo de compensação e os algoritmos responsáveis da comunicação digital, as modificações no circuito de controle da corrente de laço para permitir a modulação do sinal de 1200 Hz e 2200 Hz usado pela comunicação digital, e o projeto de alimentação do transmissor, que foi projetado visando a eficiência para respeitar os limites de consumo de corrente. Os resultados obtidos com essa nova arquitetura, apresentam que são mantidas as características dos transmissores 4-20 mA usados como base, e que a medição digital tem um nível de erro 0,05 %FS (porcentagem de fundo de escala) menor do que a saída analógica do mesmo transmissor, valor considerável comparado com o 0,2 %FS que é o nível de erro total do sistema. Os protótipos usados para as medições foram caracterizados num processo que levou 35 dias de operação continua, validando assim o projeto elétrico e software desenvolvido.
Title in English
Development of a piezoresistive pressure transmitters with hart communication protocol.
Keywords in English
Digital communication
Electronic devices
Microelectronics
Sensor
Abstract in English
This thesis consists of a technical research (P&D) on technological innovations of a highly accurate intelligent pressure transmitter using a HART protocol and piezoresistive sensors in collaboration with LSI-USP / MEMS Ltda. The outcome consists of a prototype of a competitive product in the Brazilian market. This project presents a product architecture based on highly accurate 4-20mA MEMS Ltda. transmitters. It maintains the features necessary for analogical measurements and adds components, which are compatible with the functions of HART with a Bell 202 physical layer. In addition to the architecture, this document presents the development of: interfaces between the compensation algorithm and digital communication algorithms, modifications of the current loop control circuit to allow signal modulation used by digital communications of 1200Hz and 2000Hz, a voltage source project, which envisioned efficiency and considered the limits of current consumption. Results of this architecture show that the 4-20mA transmitter´s characteristics, used as a starting point for the product, are maintained and that digital measurements present 0.05%FS (Full Scale) less error than analogical measurements taken by the same transmitter. This presents a significant error reduction when compared to the total error of the system, which is 0, 2 %FS. The prototypes used for measurements were tested during 35 continuous days, validating their electrical installation and software.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-03-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.