• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2018.tde-18072018-135559
Documento
Autor
Nombre completo
Raphael Garcia Moreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
Santos Filho, Sebastião Gomes dos (Presidente)
Mansano, Ronaldo Domingues
Santos, Edson Tafeli Carneiro dos
Silva, Maria Lucia Pereira da
Siqueira, Cesareo de La Rosa
Título en portugués
Fabricação e modelagem de uma nova geometria para espectrometria de mobilidade iônica de tolueno, propanol e água com elevada relação sinal-ruído.
Palabras clave en portugués
Descarga elétrica
Espectrometria
Espectrômetro
Ionização de gases
Relação entre sinal e ruído
Resumen en portugués
Neste trabalho é apresentada uma nova geometria e os critérios de projeto para dispositivos de espectrometria de mobilidade iônica, com objetivo de aumentar a relação entre sinal e ruído detectados pelos eletrômetros que compõem a região de detecção, quando associado à ionização baseada em descargas elétricas que tipicamente emitem maior interferência eletromagnética em relação a outros tipos de ionização. A geometria e os critérios de projeto foram estabelecidos com o auxílio do simulador de trajetórias iônicas SIMION versão 8.1 e comparada com espectrômetros de mobilidade iônica do estado-da-arte. Os resultados das simulações dos dispositivos foram avaliados por meio dos testes estatísticos não-paramétricos de Iman-Davenport e Holm. O resultado indicou que a geometria proposta apresentou compatibilidade com as melhores características dos espectrômetros atuais com confiança estatística a 95 %. Na sequência a geometria proposta foi simulada, fabricada e testada para detecção dos íons de: tolueno - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) e água - H2O (H+, HO+, H2+, O+). Os picos de corrente iônica detectada nos eletrômetros indicaram coerência com as trajetórias simuladas para estes conjuntos de íons. Além disso, os resultados experimentais apresentaram um aumento na relação entre sinal e ruído para a nova geometria proposta que foi validada pelo teste de comparação pareada não-paramétrico de Wilcoxon a 95 % de confiança estatística.
Título en inglés
Fabrication and modeling of a new geometry for ion mobility spectrometry of toluene propanol and water with high signal-to-noise ratio.
Palabras clave en inglés
Discharge ionization
Ion mobility spectrometry
Signal-to-noise ratio
Spectrometer
Resumen en inglés
In this work, a new geometry and a design criteria for ion mobility spectrometry devices was presented, aiming to increase the signal-to-noise ratio detected by electrodes of the detection region, when associated with ionization based on electrical discharges. The new geometry and the design criteria were established in the SIMION version 8.1 (an ionic trajectory simulator) and compared with the state-of-art ion mobility spectrometers. The results from device simulations were evaluated using the non-parametric statistical test of Iman-Davenport and Holm. The result indicated that the proposed design criteria presented compatibility with the best characteristics of current spectrometers with statistical evidence at 95%. The proposed geometry was simulated, fabricated and tested for the following solvents: toluene - C7H8 (C5H5+, C6H5+, C7H7+), propanol - C3H8O (CH3+, CH3O+, C2H3+, C2H4O+, C2H5O+, C3H6+, C3H7+, C3H7O+) and water - H2O (H+, HO+, H2+, O+). The peaks of ion current detected in the electrometers occurred at approximate positions of the simulated trajectories for these sets of ions. In addition, the experimental data showed an increase in the signal-to-noise ratio for the proposed new geometry that was validated by the test statistic of Wilcoxon signed rank at 95% statistical confidence.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-07-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.