Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2008.tde-02062008-143539
Document
Author
Full name
Flávia Rodrigues de Oliveira Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2008
Supervisor
Committee
Courrol, Lilia Coronato (President)
Mansano, Ronaldo Domingues
Vieira, Martha Marques Ferreira
Title in Portuguese
Desenvolvimento de um biossensor de peróxido de hidrogênio de baixo custo baseado na emissão do európio III.
Keywords in Portuguese
Compostos orgânicos
Equipamentos de medidas elétricas
Európio
Fotônica
Sensores biomédicos
Abstract in Portuguese
Neste trabalho estudou-se as propriedades ópticas do complexo Európio- Tetraciclina (EuTc), determinando as melhores condições para se obter uma formação eficiente do complexo. Parâmetros ópticos como absorção, emissão, tempo de vida e índice de refração foram obtidos. Variação da concentração de európio no complexo, da temperatura, pH ótimo e tempo de reação das soluções foram analisados. Um aumento na banda de emissão do európio foi observado com adição de peróxido de hidrogênio (HP) na solução. As amostras foram preparadas com pH neutro e a luminescência visível do lantanídeo foi detectada após uma incubação das amostras por 30 min. Um método direto para determinação de peróxido de uréia (PHU) e colesterol, em solução, usando a fluorescência do complexo EuTc é descrito. Os resultados mostram que o complexo é ainda mais sensível para o peróxido de uréia, aumentando a intensidade de emissão em até 40 vezes, do que para o peróxido de hidrogênio, que proporciona um aumento máximo de 15 vezes, quando comparados ao EuTc puro. É reportado também, pela primeira vez, que para a determinação do colesterol total, utilizando-se a sonda EuTc, não há necessidade de adição de enzima na solução, além de ser capaz de detectar frações de colesterol (LDL, VLDL e HDL), também sem adição de outros reagentes. Esse método mostra que o complexo pode ser usado como biossensor de alta sensibilidade, boa precisão, resposta rápida, baixo custo e resultados reprodutíveis para a determinação direta do peróxido de hidrogênio, do peróxido de uréia, de colesterol e LDL e para a determinação indireta da glicose. Uma proposta para a construção de um protótipo de equipamento para medidas de emissão do európio, miniaturizado, portátil, e de baixo custo, que possa ser utilizado com maior facilidade e rapidez, é apresentado.
Title in English
Development of a low cost hydrogen peroxide biosensor based on europium (III).
Keywords in English
Cholesterol
Europium
Glucose
Hydrogen peroxide
LED
Photodiode
Tetracycline
Urea hydrogen peroxide
Abstract in English
In this work was studied the optical properties of Europium-Tetracycline complex (EuTc), determining the best conditions to obtain an efficient complex formation. Optical parameters as absorption, emission, lifetime and refractive index were obtained. Variation of europium complexes concentration, temperature, optimal pH and solutions time reaction were analyzed. An increase in the europium emission band was observed with the addition of hydrogen peroxide (HP) in the solution. The samples were prepared with neutral pH and the lanthanide visible luminescence was detected after a samples incubation of 30 min. A direct method to determine urea hydrogen peroxide (PHU) and cholesterol, in solution, using a fluorescent EuTc complex is described. The results show that the complex is more sensitive for urea hydrogen peroxide, it is over fortyfold higher, while for hydrogen peroxide the increasing is fifteenfold higher when compared to pure EuTc complex emission intensity. It is also reported, for the first time, for the determination of cholesterol total, using the EuTc probe, the enzymatic reaction is not necessary, and also is possible to detect cholesterol fractions (LDL, VLDL and HDL), without the addition of other reagents. This method shows that the complex can be used as a biossensor of high sensibility, good accuracy, fast response, low cost and reproducible results to direct determination of hydrogen peroxide, urea hydrogen peroxide, cholesterol and LDL, and to indirect determination of glucose. A prototype for the construction of miniaturized equipment, portable, low cost, easier and faster to be used, is presented.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2008-07-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.