Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2008.tde-30052008-152431
Document
Auteur
Nom complet
Ana Paula Brambila
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Costa, Oswaldo Luiz do Valle (Président)
Itiki, Cinthia
Yoneyama, Takashi
Titre en portugais
Detecção automática de fibrilação atrial através de modelos Markovianos.
Mots-clés en portugais
Arritmia
Cadeias de Markov
Resumé en portugais
A fibrilação atrial (FA) é um dos tipos mais freqüentes de arritmia cardíaca e é caracterizada principalmente pela aleatoriedade na ocorrência dos batimentos do coração. Sob este aspecto, a fibrilação atrial pode ser considerada um processo estocástico e por isso tem sido freqüentemente modelada através de cadeias de Markov. Seguindo trabalhos anteriores sobre este tópico, este trabalho modela seqüências temporais de batimentos cardíacos como um processo markoviano de três estados para detecção automática de FA. O modelo foi treinado e desenvolvido através dos sinais da base de dados MIT-BIH. Outro método mais consolidado na detecção de FA, denominado "Razão RR", também foi implementado, com o objetivo de comparar os resultados do Modelo Markoviano. A avaliação de desempenho para ambos os métodos implementados fo i realizada medindo-se a sensibilidade (Se) e o valor preditivo positivo (+P) para a detecção de FA. Estes dois métodos - Modelos Markovianos e "Razão RR" - tiveram seus coeficientes e limiares otimizados com o objetivo de maximizar, ao mesmo tempo, os valores de Se e +P. Após a otimização, ambos os métodos foram testados com uma nova base de dados, independente da base de dados de desenvolvimento. Os resultados obtidos com a base de dados de teste foram Se=84,940% e +P=81,579%, consolidando os Modelos Markoviano s para detecção de batimentos aleatórios.
Titre en anglais
Atrial fibrillation automatic detection through Markov models.
Mots-clés en anglais
Atrial fibrillation
ECG
Markov chain
Resumé en anglais
Atrial fibrillation (AF) is one of the most common cardiac arrhythmia and it is mainly characterized by the presence of random RR intervals. In this way, atrial fibrillation has been studied as a stochastic process and it has been often modeled through Markov chains. Following previous studies on this subject, this work models time sequences of heartbeats as a three states Markov process for AF automatic detection. The model was trained and developed using signals from MIT-BIH database. Another consolidated method for AF detection, called "RR Ratios", was also applied to compare Markov Model's results. The performance evaluation of both methods was measured through sensitivity (Se) and positive predictive (+P) for AF detection. These two methods - Markov Model and "RR Ratio" - had their coefficients and thresholds optimized in order to maximize the values of Se and +P at the same time. After optimization, both methods were tested with another database, independent of development database. The obtained results were Se = 84,940% and +P = 81,579%, consolidating Markov Models for detecting random heartbeats.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2008-07-02
 