Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2016.tde-17062016-132441
Documento
Autor
Nombre completo
César Augusto Palacio Dantas
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Kassab Junior, Fuad (Presidente)
Martini, Jose Sidnei Colombo
Netto Junior, Arthur Vieira
Título en portugués
Desenvolvimento e aplicação do índice de desempenho energético da iluminação pública utilizando lógica nebulosa: estudo de caso da Cidade Universitária "Armando de Salles Oliveira" da Universidade de São Paulo.
Palabras clave en portugués
Eficiência e racionalidade energética
Energia elétrica (Eficiência)
Iluminação pública
Sistema de inferência nebulosa
Resumen en portugués
A eficiência e a racionalidade energética da iluminação pública têm relevante importância no sistema elétrico, porque contribui para diminuir a necessidade de investimentos na construção de novas fontes geradoras de energia elétrica e nos desperdícios energéticos. Apresenta-se como objetivo deste trabalho de pesquisa o desenvolvimento e aplicação do IDE (índice de desempenho energético), fundamentado no sistema de inferência nebulosa e indicadores de eficiência e racionalidade de uso da energia elétrica. A opção em utilizar a inferência nebulosa deve-se aos fatos de sua capacidade de reproduzir parte do raciocínio humano, e estabelecer relação entre a diversidade de indicadores envolvidos. Para a consecução do sistema de inferência nebulosa, foram definidas como variáveis de entrada: os indicadores de eficiência e racionalidade; o método de inferência foi baseado em regras produzidas por especialista em iluminação pública, e como saída um número real que caracteriza o IDE. Os indicadores de eficiência e racionalidade são divididos em duas classes: globais e específicos. Os indicadores globais são: FP (fator de potência), FC (fator de carga) e FD (fator de demanda). Os indicadores específicos são: FU (fator de utilização), ICA (consumo de energia por área iluminada), IE (intensidade energética) e IL (intensidade de iluminação natural). Para a aplicação deste trabalho, foi selecionada e caracterizada a iluminação pública da Cidade Universitária "Armando de Salles Oliveira" da Universidade de São Paulo. Sendo assim, o gestor do sistema de iluminação, a partir do índice desenvolvido neste trabalho, dispõe de condições para avaliar o uso da energia elétrica e, desta forma, elaborar e simular estratégias com o objetivo de economizá-la.
Título en inglés
Development and application of energy performance index of public lighting using fuzzy logic: a case study of University City "Armando de Salles Oliveira" of the Universidade de São Paulo.
Palabras clave en inglés
Efficiency and rationality
Electricity
Fuzzy inference system
Lighting
Resumen en inglés
The energy efficiency and rationality of public lighting have great importance in the electrical system, because it contributes to reduce the need for investment in building new sources of power and energy waste. It presented as objective of this work research development and application of IDE (Energy Performance Index), based on the fuzzy inference system and indicators of efficiency and rationality of use of electricity. The option to use the fuzzy inference is due to the facts of his ability to play part of human reasoning, and establish the relationship between indicators of diversity involved. To achieve the fuzzy inference system, it was defined as input variables: the efficiency and rationality indicators; the inference rules-based method was produced by expert in public lighting and as output a real number that characterizes the IDE. Efficiency and rationality indicators are divided into two classes: global and specific. The global indicators are: PF (power factor), FC (load factor) and FD (demand factor). Specific indicators are: FU (utilization factor), ICA (energy consumption per lit area), IE (energy intensity) and IL (daylight intensity). For the application of this work was selected and characterized the public lighting of the University City "Armando de Salles Oliveira" the University of São Paulo. Thus, the lighting system manager from the index developed in this work, have conditions to evaluate the use of electricity and thus prepare and simulate strategies in order to save it.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
cesarapdantas.pdf (2.16 Mbytes)
Fecha de Publicación
2016-06-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.