Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2011.tde-03052012-122930
Documento
Autor
Nombre completo
Bruno Bestle Turrin
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Kassab Junior, Fuad (Presidente)
Campo, Alexandre Brincalepe
Marques, Ricardo Paulino
Título en portugués
Projeto e desenvolvimento de um sistema de controle para um dispositivo de ventilação mecânica pulmonar.
Palabras clave en portugués
Sistemas de controle
Sistemas mecânicos (modelagem matemática)
Ventilador mecânico pulmonar
Resumen en portugués
A ventilação mecânica pulmonar é a substituição da respiração espontânea de um paciente quando este não realiza ou realiza parcialmente esta tarefa. Esta ventilação é de extrema importância para o tratamento de pacientes em estado crítico em unidades de terapia intensiva e para a manutenção da oxigenação sanguínea durante cirurgias. A ventilação mecânica pulmonar consiste em empurrar os gases para dentro do pulmão de forma controlada, mantendo uma pressão inspiratória ou um volume inspiratório determinado. Além disso, controla o nível de pressão durante a expiração do paciente para manter os alvéolos abertos e dificultar lesões internas. Este trabalho se propõe a caracterizar uma especificação de engenharia para os sistemas de controle de ventilação, se baseando em características fisiológicas do sistema respiratório do paciente saudável e também com patologias conhecidas. São apresentados modelos matemáticos para os sistemas mecânicos responsáveis pela atuação na inspiração e na expiração do paciente, bem como um modelo matemático para o sistema respiratório. Foram desenvolvidos sistemas de controle, baseados no controlador PID, para os principais tipos de modalidades ventilatórias. Os sistemas controlados foram simulados e os resultados são apresentados neste trabalho. Os controles propostos foram implementados em equipamentos de anestesia e UTI projetados na K. Takaoka Ind. Com. Prod. Hosp. LTDA. entre 2008 e 2010 no Brasil, e estão sendo usados hoje nas salas de cirurgia e centros de terapia intensiva pelo Brasil e em alguns países da América do Sul e do Oriente médio.
Título en inglés
Project and development of a control system for a lung mechanical ventilation device.
Palabras clave en inglés
Control systems
Mathematical models
Mechanical systems
Pneumatic systems
Pulmonary mechanical ventilation
Resumen en inglés
The mechanical ventilation is the replacement of spontaneous breathing of a patient when it does not perform or partially perform this task. This ventilation is extremely important for the treatment of critically ill patients in intensive care units and for the maintenance of blood oxygenation during surgery. The mechanical ventilation consists in pushing the gas into the lungs in a controlled manner, maintaining a determined inspiratory pressure or inspiratory volume. In addition, it has to control the pressure level during the patients exhalation to keep the alveoli opened and prevent internal injuries. This work aims to characterize an engineering specification for the control systems of ventilation, relying on physiological characteristics of the patient's respiratory system on healthy subjects and also subjects with known diseases. Here are presented mathematical models for the mechanical systems responsible for acting on the inspiration and expiration of the patient, as well as a mathematical model for the respiratory system. There were developed control systems, based on the PID controller for the main types of ventilation modes. Controlled systems were simulated and the results are presented in this dissertation. The proposed controls were implemented in anesthesia and intensive care equipments designed in K. Takaoka Ind. Com Prod. Hosp. LTD. between 2008 and 2010 in Brazil, and are being used today in the operating rooms and intensive care centers in Brazil and some countries in South America and the Middle East.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-05-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.