• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2014.tde-14122014-175208
Document
Auteur
Nom complet
Lucio Salles de Salles
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Balbo, José Tadeu (Président)
Mello, Luiz Guilherme Rodrigues de
Severi, Andréa Arantes
Titre en portugais
Análise do comportamento de pavimento experimental de concreto continuamente armado de curta extensão.
Mots-clés en portugais
Curta extensão
Deflexões
Desempenho
Fissuração
Pavimento de concreto continuamente armado
Tensões
Resumé en portugais
O pavimento de concreto continuamente armado (PCCA) é caracterizado pela presença de uma alta taxa de armadura longitudinal localizada acima do meio da placa; essa armadura possibilita ao pavimento uma placa de concreto sem juntas. Diferentemente do pavimento de concreto simples, no PCCA não há uma indução da fissuração; as fissuras ocorrem de maneira aleatória, porém são mantidas fortemente apertadas pela armadura longitudinal proporcionando uma estrutura de alta durabilidade exigindo o mínimo de manutenção. Perante tais benefícios, decidiu-se construir quatro seções experimentais deste pavimento no campus da Universidade de São Paulo. A maior diferença entre o PCCA experimental e aqueles encontrados na literatura técnica é a extensão; com o intuito de simular uma parada de ônibus, cada seção possui 50 metros de comprimento, curtas em comparação com os até 400 metros de comprimento encontrados em PCCA tradicionais. Para analisar o comportamento do pavimento foram esquematizados três estudos de desempenho: levantamentos de fissuras; testes de deformação com provas de carga dinâmicas (PCD) com um caminhão carregado; e testes de deflexões com o Falling Weight Deflectometer (FWD). A análise da fissuração mostra um comportamento bastante distinto daquele encontrado em PCCA tradicionais; a curta extensão, aliada à falta de ancoragem da placa, resultou em uma fissuração bastante tardia e em um elevado espaçamento entre fissuras. A seção 1, não apresenta, até esta data (dezembro de 2013), nenhuma fissura. A pouca fissuração sugeriu a hipótese de que as fissuras estariam invisíveis a olho nu em função do forte efeito de amarração das barras longitudinais. Entretanto, apesar de tais diferenças, o estudo das tensões através das deformações obtidas pelos strain gauges nas PCD apontam um desempenho estrutural adequado do pavimento; as tensões de tração na flexão resultaram em valores bastante inferiores à resistência do concreto, assegurando a qualidade da placa. Além destas afirmações, as PCD possibilitaram uma série de análises de tensões com configurações de carregamento diferentes. O estudo de deflexões mostrou que nas proximidades da borda longitudinal do pavimento, as deflexões são maiores devido à falta de ancoragem do sistema; no centro as deflexões foram típicas de pavimentos de concreto. A retroanálise das bacias de deflexão resultou em valores de módulo de elasticidade e módulo de reação do subleito baixos próximos à borda, reforçando o impacto da falta de ancoragem. A análise da eficiência de transferência de carga entre fissuras mostrou um desempenho altamente satisfatório de todas as fissuras, inclusive aquelas mais próximas das bordas, o que, novamente, certifica a integridade estrutural da placa.
Titre en anglais
Performance analysis of short experimental continuously reinforced concrete pavement.
Mots-clés en anglais
Continuously reinforced concrete pavement
Cracking
Deflections
Performance
Short length
Stresses
Resumé en anglais
The continuously reinforced concrete pavement (CRCP) is characterized by the presence of a high longitudinal reinforcement percentage located above the slabs middle; this steel allows a concrete slab without joints. Unlike jointed plain concrete pavements, the CRCP has no cracking induction; the cracks occur randomly, but are held strongly tight by the longitudinal steel, thus, providing a highly durable structure that requires minimal maintenance. Given these benefits, it was decided to build four experimental sections of this pavement on the University of São Paulo's campus. The biggest difference between the experimental CRCP and those found in the technical literature is the length; in order to simulate a bus stop, each section is 50 meters long, short compared to traditional PCCA up to 400 meters long. To analyze the behavior of the pavement, three performance studies were carried out: cracks surveys; strain tests with dynamic load tests (DLT) with a loaded truck; and Falling Weight Deflectometer (FWD) deflection testing. The analysis shows that the cracking pattern is quite distinct from that found in traditional PCCA, the short extension, coupled with the slabs lack of anchorage, resulted in a late cracking development and in large crack spacing. Section 1, has yet to develop any cracks. The low cracking suggested the hypothesis that the cracks were invisible to the naked eye due to the longitudinal bars strong binding effect. However, despite these differences, the stress study through strains obtained by strain gauges in DLT indicate an appropriate structural performance of the pavement, the flexural tensile stresses resulted in values well below the concretes strength, ensuring the slabs quality. Also, the DLT enable a series of stresses analysis with different load configurations. The deflection study showed that in the longitudinal edges vicinity, deflections are higher due to lack of any anchorage system; the center deflections are typical concrete pavement ones. The deflection basins backcalculation resulted in values of elasticity modulus of concrete and modulus of subgrade reaction lower near the edge, reinforcing the impact of the lack of anchorage. The analysis of the load transfer efficiency across cracks showed highly satisfactory performance of all cracks, including those nearest to the edge, which certifies the structural integrity of the slab.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
DISSERTACAO_LUCIO.pdf (35.85 Mbytes)
ERRATA_DISSERTACAO.pdf (41.61 Kbytes)
Date de Publication
2015-01-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.