Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2013.tde-21102014-111526
Document
Author
Full name
Victor Sette Gripp
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2013
Supervisor
Committee
Kulay, Luiz Alexandre (President)
Andrade, Vívian Tavares de
Seckler, Marcelo Martins
Title in Portuguese
Análise ambiental, energética e econômica de arranjo processual para reúso de água em refinaria de petróleo.
Keywords in Portuguese
Análise econômica
Avaliação do Ciclo de Vida (ACV)
Demanda Cumulativa de Energia (CED)
Refinaria de petróleo
Reúso de água
Abstract in Portuguese
Foi construído um modelo representativo do ciclo de vida da água em uma refinaria de petróleo, contemplando todos os usos a que esta se presta. Nesse contexto foram avaliados do ponto de vista ambiental, energético e econômico cenários em que etapas adicionais eram incorporadas ao tratamento de efluentes de forma a viabilizar o reúso de água e o fechamento do circuito na própria refinaria, reduzindo assim a necessidade de captação e, consequentemente, de tratamento da água bruta captada pela refinaria. O Cenário I corresponde ao cenário-base, sem implantação de nenhuma ação voltada ao reúso. No Cenário II, é incorporada a etapa adicional chamada Tratamento Fase 1, constituída por um processo de Clarificação seguido de uma Eletrodiálise Reversa (EDR) que permite o reúso de 255,7 m3/h dos 350 m3/h lançados inicialmente ao corpo hídrico no Cenário I. No Cenário III, é incorporada ao arranjo do Cenário II uma etapa de Cristalização Evaporativa para tratar o concentrado salino da EDR, recuperando, assim, mais 55,4 m3/h dos 350 m3/h lançados inicialmente, utilizando, para isso, vapor residual inicialmente não aproveitado pela refinaria. A análise ambiental foi desenvolvida por Avaliação do Ciclo de Vida (ACV) e constatou um desempenho muito semelhante dos três cenários. Apesar disso, a análise em perfil aberto, de impactos de midpoint, evidenciou ganhos ambientais significativos associados ao fechamento de circuito de água e, embora com vantagens muito discretas, o Cenário III apresentou um desempenho superior ao do Cenário II em todas as categorias e, na grande maioria delas, também superior ao desempenho do Cenário I. A análise de indicador único, em endpoint, destacou o impacto em Mudança Climática, relativo principalmente à queima de gás natural na caldeira para a geração de vapor, como o principal impacto ambiental associado ao ciclo de vida da água na refinaria, responsável por mais de 90% do valor correspondente ao resultado do indicador único. A análise energética foi desenvolvida utilizando-se o indicador de Demanda Cumulativa de Energia (CED) e resultou em um desempenho superior do Cenário I, ainda que com pequenas diferenças em relação aos Cenários II e III. O pior desempenho foi o do Cenário II. Comparando-se a contribuição relativa dos diferentes tipos de energia, destaca-se a energia de origem hidrelétrica, responsável por cerca de 80% do indicador único de CED em todos os três cenários. A análise econômica foi realizada por meio de indicadores tradicionalmente utilizados para a análise de viabilidade de projetos Taxa Interna de Retorno (TIR) e Valor Presente Líquido (VPL) , considerando, como referência, as regras de cobrança pelo uso da água vigentes na bacia do rio Paraíba do Sul. Com os preços cobrados atualmente pelo uso da água desta bacia, a implantação de ambos os cenários de reúso (II e III) não se viabiliza economicamente. Para que isso ocorra, o valor cobrado pelo uso da água teria que ser da ordem de 50 a 80 vezes maior do que o que é cobrado atualmente. Dentre os cenários de reúso, o Cenário II apresentou desempenho econômico superior ao do Cenário III.
Title in English
Environmental, energetic and economic analysis of a process design for water reuse in petroleum refinery.
Keywords in English
Cumulative Energy Demand (CED)
Economic analysis
Life Cycle Assessment (LCA)
Petroleum refinery
Water reuse
Abstract in English
It was built a representative model of the water life cycle within a petroleum refinery, considering all the uses in which it is applied. In this context, under environmental, energetic and economic perspective, different scenarios were analyzed, where further treatment stages were added to the wastewater treatment process so that recycled water could be provided back to the refining process, reducing, therefore, the need for freshwater intake and pretreatment by the refinery. Scenario I is the base scenario, without implementation of any water reuse aimed action. In Scenario II, it is incorporated the additional stage called Phase 1 Treatment, which consists of a Clarification process followed by an Electrodialysis Reversal (EDR).This enables the recycling of 255.7 m3/h from the 350 m3/h previously discharged to the water body in Scenario I. In Scenario III, it is incorporated to the Scenario II setting an Evaporative Crystallization process for treating the concentrated brine resulting from the EDR process. This enables the recovery of more 55.4 m3/h from the 350 m3/h initially released, using, for that, the energy from residual steam previously not used by the refinery. The environmental analysis was developed through Life Cycle Assessment (LCA) and found very similar performances for all three scenarios. Despite that, the open profile analysis, of midpoint impacts, showed significant environmental gains from the closure of the water circuit and, though with very small advantages, Scenario III showed a better performance than Scenario II in all impact categories and, in most of them, also better than Scenario I performance. The single score analysis, considering endpoint impact categories, highlighted Climate Change, specially related to the natural gas burning in the boiler for steam generation, as the main impact category associated to the water life cycle within the refinery, being responsible for more than 90% of all the value of the single score indicator. The energetic analysis was developed using the Cumulative Energy Demand (CED) indicator and resulted in a better performance of Scenario I, even if with just small differences from Scenarios II and III. The worst performance was from Scenario II. Comparing the relative contribution of the different types of energy, the hydroelectricity was the most important one, being responsible for around 80% of the CED single score in all three scenarios. The economic analysis was developed through traditional indicators used for assessing projects viability Internal Return Rate (IRR) and Net Present Value (NPV), considering, as reference, the rules of charging for water use valid nowadays at the Paraíba do Sul river basin. With the prices charged nowadays for the water use from this basin, the implementation of both reuse scenarios is not economic viable. In order to make it viable, the charged value would have to be around 50 to 80 times higher than it is today. Among the reuse scenarios, Scenario II had a better economic performance than Scenario III.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-10-23
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • ANDRADE, E. M., et al. Processo de Cristalização Evaporativa para Tratamento de Efluente Salino Industrial. In XIX Congresso Brasileiro de Engenharia Química COBEQ 2012, Búzios RJ, 2012. Anais XIX Congresso Brasileiro de Engenharia Química.Rio de Janeiro - RJ : Editora Universidade Federal do Rio de Janeiro, 2012. Dispon?vel em: http://www.cobeq2012.com.br/.
  • GRIPP, V. S., et al. Avaliação de Desempenho Ambiental de Arranjo de Processo voltado ao Tratamento de Efluentes Salinos com vistas ao Reúso de água na indústria. In XIX Congresso Brasileiro de Engenharia Química COBEQ 2012, Búzios RJ, 2012. Anais XIX Congresso Brasileiro de Engenharia Química.Rio de Janeiro - RJ : Editora Universidade Federal do Rio de Janeiro, 2012. Dispon?vel em: http://www.cobeq2012.com.br/.
  • KULAY, L., GRIPP, V. S., and SILVA, Gil Anderi da. Environmental Performance Evaluation in Brazilian esticide Sector. In IV CILCA - Conferencia Internacional de Análisis de Ciclo de Vida en Latinoamérica 2011, Coatzacoalcos, 2011. Proceedings of IV CILCA - Conferencia Internacional de Análisis de Ciclo de Vida en Latinoamérica 2011.Tlalnepantla - Mexico DF : CADIS - Centro de Analysis de Ciclo de Vida y Diseno Sustentable, 2011. Abstract. Available from: http://www.cilca2011.mx.
  • KULAY, L., VINAS, R. S., and GRIPP, V. S. Life Cycle Exergoenvironmental Analysis of Biofuels in Brazil. In Ecotech & Tools - Environmental and Integrated Assessment of Complex Systems, Montpellier, 2011. Proceedings - Ecotech&Tools - Environmental and Integrated Assessment of Complex Systems.Montpellier : CEMAGREF - France, 2011. Abstract. Available from: http://www.ecotech-tools.org/.
  • 6ª edição do Prêmio Petrobras de Tecnologia - Augusto Seabra Moggi - Categoria: Tecnologia de Preservação Ambiental - PETRÓLEO BRASILEIRO S.A.
  • Best Paper Award - 1st Place - IV Conferencia Internacional de Analisis de Ciclo de Vida en Latinoamerica - CADIS - Centro de Analysis de Ciclo de Vida y Diseno Sustentable
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.