• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.3.2010.tde-20082010-145336
Document
Author
Full name
CÍnthia Tiemi Muranaka
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Nascimento, Cláudio Augusto Oller do (President)
Delmas, Henri
Freire, Renato Sanches
Lebigue, Carine Julcour
Vianna, Marilda Mendonça Guazzelli Ramos
Title in Portuguese
Combinaçäo de adsorçäo por carväo ativado com processo oxidativo avançado (POA) para tratamento de efluentes contendo fenol.
Keywords in Portuguese
Adsorçäo
Carväo ativado (regeneraçäo)
Efluentes (tratamento)
Oxidaçäo
Abstract in Portuguese
O processo de adsorção por carvão ativado é uma técnica muito aplicada para tratamento de efluentes. Porém o tratamento que envolve adsorção não é um sistema completo, pois há a necessidade da destruição dos compostos que foram imobilizados na superfície do carvão. Frente a esse problema, métodos alternativos de regeneração de carvão ativado são investigados. Os processos Fenton e foto-Fenton são considerados tecnologias promissoras de tratamento de efluentes, e foram testados para regenerar o carvão ativado. Este trabalho objetiva estudar a adsorção de fenol em carvões ativados (CAs) e a consecutiva regeneração in-situ do carvão pela oxidação de (foto-) Fenton. Duas operações diferentes foram realizadas: 1) sistema de batelada, a fim de investigar a influência das concentrações de Fe2+ e H2O2; 2) adsorção contínua em leito fixo, seguido de circulação em batelada dos reagentes de Fenton pelo leito de CA saturado, para examinar a eficiência do processo real. Foram estudados dois tipos de carvão ativado: CA L27 (meso e microporoso) e CA S23 (somente microporoso). No reator de batelada as melhores condições encontradas para a mineralização do poluente no sistema Fenton homogêneo não são as melhores para a regeneração do CA: foi observada uma redução contínua da capacidade de adsorção do L27 após 3 oxidações, devido à redução tanto da massa do CA quanto da área superficial. Uma maior concentração de Fe2+ e menor concentração de H2O2 (2 vezes a estequiometria) levou a uma recuperação de 50% da capacidade de adsorção inicial em pelo menos 4 ciclos consecutivos para o L27, enquanto que cerca de 20% para o S23. No processo consecutivo de adsorção contínua/oxidação de Fenton em batelada, a eficiência de regeneração atinge de 30% a 40% para o L27 após dois ciclos independente da concentração da alimentação e menos de 10% para o S23. O processo foto-Fenton realizado para o L27 levou à quase completa mineralização e aumentou a recuperação da capacidade de adsorção do CA (56% após dois ciclos).
Title in English
Combination of adsorption by activated carbon with advanced oxidation process (AOP) for the treatment of wastewater containing phenol.
Keywords in English
Active carbon
Adsorption
Advanced oxidation process
Reuse
Wastewater
Abstract in English
The adsorption process by active carbon is a technique applied extensively for wastewater treatment. However the tertiary treatment involving adsorption is not a complete system, since there is a need of destruction of the compounds that were immobilized on the carbon surface. In face of this problem, some alternative regeneration methods of active carbon are investigated. Fenton and photo-Fenton processes have been considered promising technologies for wastewater treatment and have been tested to regenerate the AC. The purposes of this study are the adsorption of phenol on activated carbons (ACs) and the consecutive in-situ regeneration of carbon by (photo-) Fenton oxidation. Two different operations have been carried out: 1) batch procedure in order to investigate the influence of Fe2+ and H2O2 concentrations; 2) continuous fixed bed adsorption, followed by a batch circulation of the Fentons reagent through the saturated AC bed, to examine the efficiency of the real process. Two different activated carbons have been also studied: a both micro- and mesoporous AC (L27) and an only microporous one (S23). In the batch reactor the best conditions found for pollutant mineralization in the homogeneous Fenton system are not the best for AC regeneration: a continuous reduction of adsorption capacity of L27 is observed after 3 oxidations, due to the decrease of both AC weight and surface area. Higher concentration of Fe2+ and lower concentration of H2O2 (2 times the stoechiometry) lead to a 50% recovery of the initial adsorption capacity during at least 4 consecutive cycles for L27, while about 20% for S23. In the consecutive continuous adsorption/batch Fenton oxidation process, the regeneration efficiency reaches 30% to 40% for L27 after two cycles whatever the feed concentration and less than 10% for S23. A photo- Fenton test performed on L27 shows almost complete mineralization (contrary to dark Fenton) and further improves recovery of AC adsorption capacity although not complete (56% after two cycles).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-09-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.