Estudo da viabilidade do tratamento eletromagnético para água de resfriamento em indústrias químicas.
Mots-clés en portugais
Água de resfriamento
Ciclos de concentração
Torres de resfriamento
Tratamento eletromagnético
Tratamento físico de água
Tratamento químico de água
Resumé en portugais
O segmento industrial é um grande usuário de água e, na maior parte das situações, está localizado junto a aglomerações urbanas, caracterizando situação de dificuldade na obtenção deste recurso para as suas operações. As fontes de água estão cada vez mais saturadas e os processos de tratamento mais sofisticados. O objetivo deste estudo foi avaliar a viabilidade técnico-econômica da implantação do tratamento eletromagnético para água de resfriamento em indústrias químicas, substituindo ou complementando o tratamento químico convencional. O texto descreve inicialmente os fundamentos do tratamento de água baseado na aplicação de campo eletromagnético e, em seguida, os efeitos do uso dessa tecnologia sobre custos anuais de resfriamento em um caso típico da indústria química. Neste estudo foi dada ênfase ao efeito sobre os custos anuais da menor adição de produtos químicos, redução na vazão de purga e de reposição de água, além da redução na frequência de limpeza dos equipamentos e redução da carga poluente nos efluentes líquidos. O estudo foi aplicado a uma torre de resfriamento industrial, para a qual foi elaborado um modelo matemático considerando as taxas de consumo e especificações de água de resfriamento, além de parâmetros do processo de tratamento de água convencional e eletromagnético. São apresentados resultados de um estudo de sensibilidade para diferentes cenários, em que são identificados os fatores com maior efeito sobre os custos. Além disso, na aplicação ao sistema proposto, são estimadas condições ótimas de operação, considerando os ciclos de concentração para os quais pode haver maior redução de custos. Utilizando-se o tratamento eletromagnético para a água de resfriamento, há uma economia significativa, pois o número de paradas para a manutenção dos equipamentos pode ser reduzido. Dessa forma, o produto final do trabalho constitui-se em uma estrutura de cálculo voltada à estimação de custo do tratamento físico de água de resfriamento, o qual pode ser aplicado a diferentes cenários e condições de operação industrial.
Titre en anglais
Study of the feasibility of electromagnetic treatment for cooling water in chemical industries.
Mots-clés en anglais
Concentration cycles
Cooling tower
Cooling water
Electromagnetic treatment
Water treatment
Resumé en anglais
The industrial sector is a major water user and in most situations is located next to urban areas, in a situation of increasing difficulty in collecting and treating water resources for its operations. The water sources are becoming more saturated and thus demanding more sophisticated treatment processes. The aim of this study was to evaluate the technical and economic feasibility of the implementation of electromagnetic treatment of cooling water in chemical industries, thus replacing or complementing the conventional chemical treatment. The text initially describes the principles of the physical process for water treatment based on the application of an electromagnetic field, and then focuses on the effects of the use of this technology on the annual costs of cooling in a typical case of the chemical industry. The study is focused on the effects of the electromagnetic treatment on the annual cost of cooling in view of the reduced consumption of chemicals, as well as reduction in purge flow and water replacement, reduced frequency of equipment cleaning, and reduction of pollution load caused by wastewater. The study results were applied to an industrial cooling tower for which a mathematical model was developed by considering consumption rates and cooling water specifications, as well as parameters of the electromagnetic and conventional water treatment processes. A sensitivity study was carried out for different scenarios, in which the most important factors affecting the annual cost are identified, and optimal process conditions are estimated for maximum concentration cycles. The study shows that the use of electromagnetic treatment for cooling water results in significant savings due to the reduced number of maintenance periods. The final product of this study is a calculation structure for cost estimation related to the physical treatment of cooling water, which can be applied to different scenarios and industrial operation conditions.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-07-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.