Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2011.tde-20032012-160003
Document
Author
Full name
Ísis Santos Costa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Park, Song Won (President)
Rangel, Leonardo Paes
Vianna Júnior, Ardson dos Santos
Title in Portuguese
Modelagem do escoamento em reator catalítico de membrana cerâmica para hidrogenação parcial trifásica.
Keywords in Portuguese
Catalisadores
Dinâmica dos fluidos
Reações heterogêneas
Simulação (modelagem computacional)
Abstract in Portuguese
No presente trabalho, foi desenvolvido um modelo para o escoamento em reator de membrana do tipo contator ativo, através da abordagem de dinâmica dos fluidos computacional (CFD), utilizando o código comercial ANSYS FLUENT. O modelo incluiu todo o módulo de membrana constituído por uma membrana tubular e um casco metálico. A reação modelo estudada foi a hidrogenação parcial de 1,5-ciclooctadieno, realizada pelo bombeamento da mistura reacional, dissolvida em n-heptano, através da membrana, a partir das extremidades do tubo. Como catalisador, considerou-se a presença de nanopartículas de Pd impregnadas na membrana. O meio poroso foi aproximado por leito granular representado pela equação de Ergun, tendo como parâmetros a porosidade e o tamanho de grão da membrana de alfa-Al2O3 . O valor para o tamanho de grão foi adotado como equivalente ao diâmetro de partícula determinado com uso do código aberto de estereologia ImageJ, do instituto Nacional de Saúde dos Estados Unidos. O modelo de turbulência adotado foi o RNG k-epsilon. Um estudo de sensibilidade incluiu simulações comparando escoamento desprezando reações como escoamento reativo, variação da velocidade, alteração da saída do fluxo e ativação de modelo de turbulência no meio poroso. Foram realizadas simulações de defeitos estruturais na membrana, correspondendo a regiões de porosidade alterada, com e sem perda de sua uniformidade azimutal. Conclui-se que a presença de defeitos estruturais que afetem a uniformidade azimutal da membrana pode resultar em sensível alteração do escoamento em CMRs.
Title in English
Modeling flow in ceramic catalytic membrane reactor for partial three-phase hydrogenation.
Keywords in English
Catalytic membrane reator
Computational fluid dynamics
Abstract in English
This study focused on the development of a model for the flow in a reactor membrane of the type active contactor, approached through computational fluid dynamics (CFD), using the commercial code ANSYS FLUENT. The model included the entire membrane module, consisted of a tubular membrane and a metal shell. The model reaction studied was the partial hydrogenation of 1,5-cyclooctadiene initiated by the pumping of the reaction mixture, dissolved in n-heptane, through the membrane, from the ends of the tube. As a catalyst, the study considered the presence of impregnated Pd nanoparticles in the membrane. The porous medium was approximated by a granular bed as represented by the Ergun equation, having as parameters the porosity and the grain size of the alfa-Al2O3 membrane. The value for the grain size was adopted as equivalent to particle diameter determined through the open source stereology software ImageJ, of the National Institute of Health USA. The turbulence model used was the RNG k-epsilon. A sensitivity study included simulations of flow neglecting and including reactions, speed variation, change the flow outlet and activation of turbulence model in the porous media. Simulations of structural defects in the membrane were performed, defining regions of porosity changes with and without loss of azimuthal uniformity. The conclusion was that the presence of structural defects that affect the azimuthal uniformity of the membrane can result in marked alteration of the flow regime in CMRs.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
DISSERTACAO_ISIS.pdf (21.46 Mbytes)