• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2010.tde-17032011-084822
Document
Auteur
Nom complet
Thales Pires Dias Galuchi
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Guardani, Roberto (Président)
Borges, Fúlvia Jung
Mierzwa, José Carlos
Titre en portugais
Montagem e caracterização de unidade de eletrodiálise em escala de laboratório para tratamento de soluções salinas.
Mots-clés en portugais
Dessalinização
Eletrodiálise (tratamento de água)
Membranas de separação
Processos de separação
Resumé en portugais
A escassez de água nos grandes centros urbanos deve se agravar nos próximos anos. Novas fontes de água são necessárias para suprir a demanda. Nas cidades não há disponibilidade de terrenos para construção de estações de tratamento de águas e esgotos convencionais. Por isso, são necessários novos processos de tratamento. Processos de separação por membranas como osmose reversa e eletrodiálise são usados na dessalinização de águas e efluentes. Para a realização do estudo foi montada unidade de eletrodiálise em escala de laboratório. Na montagem selecionaram-se equipamentos que fossem resistentes à salinidade das soluções. As bombas magnéticas deveriam, ainda, superar a perda de cargas causada pelas membranas. As membranas foram adquiridas no exterior; os equipamentos, no mercado local. Os experimentos foram realizados em duas etapas: exploratória e comparativa. Eles seguiram os planejamentos de fatorial e do tipo Doehlert, respectivamente. Estudou-se a dessalinização de soluções aquosas unitárias (NaCl, Na2SO4, MgCl2 e KCl), com salinidade similar à água marinha (3,5%). Obtiveram-se como respostas os fluxos de sal, de água e consumo de energia em função dos fatores envolvidos no processo. Análises estatísticas propiciaram relacionar os fatores estudados com os resultados empíricos. Os fluxos salinos são proporcionais às densidade de corrente aplicadas e não apresentaram diferenças significativas entre si. Observou-se que o fluxo de água é relevante pelo mecanismo de solvatação de íons removidos e pela osmose. O consumo de energia é proporcional à densidade de corrente e maior para os sais bivalentes.
Titre en anglais
Assembly and characterization of unit electrodialysis in laboratory scale for treatment of saline solutions.
Mots-clés en anglais
Desalination
Electrodialysis (water treatment)
Membrane separation
Separation process
Resumé en anglais
Water shortage in urban centers is expected to get worse in the next years. New water sources are necessary to meet demand. At urban area there are no available lands to build conventional water and sewage treatment plants. Therefore, new treatment processes are needed. Membrane processes like reverse osmosis and electrodialysis are used in water and wastewater desalination. A lab-scale electrodialysis unit was assembled for the study, based on a stack of electrodialysis membranes and support components that are capable of resisting solution salinity. The membrane stack was imported; the other equipment, obtained locally. The experiments were divided in two phases: exploratory and comparative. The experiments followed factorial and Doehlert designs, respectively. The desalination of aqueous solutions containing different inorganic salts (NaCl, Na2SO4, MgCl2 e KCl) in seawater salinity (3.5% mass) was studied. The responses were the salt and water fluxes and energy consumption in function of the processes variables selected. By means of a statistical analysis, it was possible to obtain the correlations for the studied factors based on the experimental results. The salt fluxes are proportional to the applied current density and they are not significantly different for the salts included in the study. It was observed that the water fluxes are relevant due to solvation of removed ions and osmosis. The energy consumption is proportional to current density and is larger for bivalent salts.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-04-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.