• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2012.tde-03072013-112013
Document
Author
Full name
Débora Pereira Coutinho da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2012
Supervisor
Committee
Guardani, Roberto (President)
Moraes, José Ermírio Ferreira de
Teixeira, Antonio Carlos Silva Costa
Title in Portuguese
Estudo para otimização do projeto de um sistema de reatores para o tratamento fotoquímico de efluentes industriais.
Keywords in Portuguese
Efluentes (tratamento químico)
Reatores bioquímicos
Abstract in Portuguese
O presente trabalho objetivou estudar aspectos relacionados ao projeto de processos de tratamento de águas efluentes industriais baseados em reatores fotoquímicos. Estudou-se uma unidade de tratamento constituída por um reator solar tubular com coletores parabólicos compostos, o qual opera acoplado a um reator com lâmpadas do tipo tanque. O modelo matemático para simulação do processo foi adaptado a partir dos resultados experimentais obtidos em trabalhos anteriores da equipe de pesquisa deste Departamento, principalmente por Ribeiro (2009). O modelo matemático foi validado por meio de simulações para o sistema operando em regime transiente. O modelo matemático foi adaptado à configuração aqui estudada, de modo a poder ser aplicado ao sistema de reatores operando em regime contínuo, isto é, com alimentação e retirada de material constantes ao longo do tempo. Foi realizado, inicialmente, um estudo de sensibilidade desse modelo em relação às variáveis de processo, baseado em simulações para volumes diferentes do reator solar e reator multi-lâmpadas. A otimização do sistema teve o objetivo de selecionar as configurações do sistema que representam mínimo custo, para os diferentes cenários estudados, para uma concentração especificada de contaminante na corrente de saída. O problema de otimização foi baseado no método da função de penalidade, em que a função de restrição é inserida na função objetivo, transformando assim o problema de otimização num problema irrestrito. O procedimento de busca utiliza o Método Simplex modificado de Nelder e Mead. Para os diferentes cenários estudados, foi comprovado que o fator determinante do custo horário de tratamento fotoquímico é o custo do reagente peróxido de hidrogênio, seguido pelo custo de energia elétrica, custo de investimento do reator de lâmpadas, custo de investimento do reator e das bombas e, por último, o custo de investimento do reator solar. A imposição de limites mais rigorosos para a concentração de saída do efluente faz com que o custo de tratamento seja proibitivo. Portanto, nestes casos é mais interessante, do ponto de vista econômico, utilizar primeiro o processo foto-Fenton até o efluente atingir o limite de biodegradabilidade de 300 mgC/L e, em seguida, submeter este efluente ao tratamento biológico (de menor custo).
Title in English
Study for design optimization of a system of reactors for the photochemical treatment of industrial effluents.
Keywords in English
Effluent treatment
Mathematical modeling
Optimization
Photo-Fenton
Photocatalysis
Abstract in English
The aim of the present study was to investigate aspects related to the design of processes for treating industrial wastewater based on photochemical reactors. The system consisted of a solar tubular reactor with compound parabolic collectors, which operates connected to a multi-lamp stirred tank reactor. The mathematical model for simulating the process was adapted from previous results obtained by the research team of this Department, mainly by Ribeiro (2009). The model was validated by comparing simulation and experimental results obtained with a pilot plant operating in transient regime. The mathematical model was adapted to the configuration in this paper, so that it could be applied to the reactor system operating in continuous regime, i.e., with constant flow rate of the input and output streams. A sensitivity analysis of this model was carried out in relation to process variables, based on simulations for different volumes of the solar reactor and multi-lamp reactor. The optimization of the system aimed to select configurations that represent minimum cost for different scenarios studied for a specified output contaminant concentration. The optimization was based on the penalty function method, in which the restriction function was inserted in the objective function, so as to transform the optimization problem into an unconstrained one. The search procedure was based on the modified Simplex method of Nelder and Mead. For the different scenarios studied, it was verified that the determining factor affecting the treatment cost is the cost of hydrogen peroxide, followed by the electricity cost, investment cost of the lamp reactor, investment cost of pumps and of the solar reactor. The treatment cost increases significantly when lower concentration limits are specified for the output stream. Therefore, as a general recommendation, it is more advantageous from the economic point of view to use the photo-Fenton process until the pollutant concentration is decreased to the threshold of biodegradability (adopted as 300mgC/L in the present study) and then submitting it to a biological treatment.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-07-12
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • SILVA, D. P. C., RIBEIRO, K., e GUARDANI, R. SIMULAÇÃO DE UMA PLANTA FOTOQUÍMICA SOLAR BASEADA NO PROCESSO FOTO-FENTON PARA O TRATAMENTO DE EFLUENTES INDUSTRIAIS. In COBEQ 2012 - Congresso Brasileiro de Engenharia Química, Búzios - RJ, 2012. Anais do COBEQ 2012 - Congresso Brasileiro de Engenharia Química., 2012.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.