Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2009.tde-11082010-160030
Documento
Autor
Nombre completo
Maurício de Carvalho Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Ruggieri, Claudio (Presidente)
Andrade, Arnaldo Homobono Paes de
Bose Filho, Waldek Wladimir
Hippert Júnior, Eduardo
Magnabosco, Rodrigo
Título en portugués
Determinação experimental da tenacidade à fratura da zona termicamente afetada de junta soldada de aço API 5L X80.
Palabras clave en portugués
Gás natural
Juntas soldadas
Mecânica da fratura
Propriedades mecânicas
Tenacidade de materiais
Resumen en portugués
Este trabalho investiga a possível correlação existente entre os baixos valores de CTOD e a ocorrência de zonas frágeis localizadas (ZFL) presentes na região de grãos grosseiros (RGG) da zona termicamente afetada (ZTA) de uma junta soldada de aço API 5L X80. Para isto, foi necessário obter corpos-de-prova SE(B) a partir de uma chapa de aço API 5L X80 a qual foi soldada numa junta ½V, para facilitar o posicionamento do entalhe na RGG da ZTA. As dimensões dos corpos-de-prova SE(B) utilizados foram espessura B=17mm, largura W=34mm, distância entre os apoios dos roletes S=138mm e uma relação entre o tamanho de trinca (a) e a largura, a/W=0,5. O entalhe posicionado na RGG da ZTA tem por objetivo evidenciar o efeito de ZFL e para tal os ensaios foram conduzidos nas temperaturas de -40ºC, - 50ºC e -70ºC. Os resultados de CTOD crítico obtidos neste estudo sugerem indícios de severa degradação da tenacidade na RGG da ZTA, provavelmente associada à formação de ZFL.
Título en inglés
Experimental assessment of heat affected zone fracture toughness of a welded API 5L X80 steel.
Palabras clave en inglés
API 5L X80
CTOD determination
Local Brittle Zones (LBZ)
Welded joints
Resumen en inglés
This work evaluates the possible correlation between low fracture toughness (critical CTOD) and local brittle zones (LBZ) occurrences in heat affected zone (HAZ) coarse grain regions. The fracture toughness of a welded API 5L X80 steel was characterized using SE(B) specimens for CTOD determination with notches located in the HAZ. The specimen dimensions are thickness B=17mm, width W=34mm, span S=138mm and crack length to width ratio, a/W=0,5. The effects of LBZ are evaluated through tests carried out in temperatures of -40ºC, -50ºC and -70ºC. The critical CTOD values obtained in this work had presented low fracture toughness and these results can be attributed to local brittle zones formed in the welding process.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-09-17
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.