Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2016.tde-07062016-145736
Document
Author
Full name
André Soares Braga
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Leal Filho, Laurindo de Salles (President)
Rodrigues, Wendel Johnson
Bergerman, Maurício Guimarães
Title in Portuguese
Medidas de dispersão de gás em células mecânicas industriais e seus condicionantes.
Keywords in Portuguese
Células mecânicas de flotação. Velocidade superficial do gás. Diâmetro de bolhas. Fluxo de superfície de bolhas. Flotação
Gases (Dispersão)
Abstract in Portuguese
A qualidade da dispersão de gás em células de flotação é comumente caracterizada através de parâmetros como velocidade superficial do gás (Jg), hold-up do gás (?g), distribuição de tamanho de bolha (db ou D3,2) e fluxo de superfície de bolha (Sb). Sendo um processo de separação de minerais que é dependente da interação (colisão + adesão) entre partículas hidrofóbicas e bolhas de ar, a flotação tem seu desempenho dependente de uma dispersão de gás apropriada na polpa de minério. Desta forma, este trabalho objetivou caracterizar o estado da dispersão de gás de duas células em um banco composto por quatro células Wemco de 42,5 m³ (subaeradas), operando em série na usina da Vale Fertilizantes (Cajati-SP). Realizaram-se três campanhas de medidas que foram conduzidas sob diferentes condições operacionais: a) Diâmetro do rotor (D) de 1,09 m e rotação (N) entre 145 RPM e 175 RPM; b) D = 0,99 m e N entre 110 RPM e 190 RPM; c) D = 0,99 m e N de 120 RPM e de 130 RPM. Observaram-se os seguintes valores de dispersão de gás: 0,7 <= Jg <= 5,4 cm/s, 7 <= ?g <= 15%, 1,6 <= D3,2 <= 2,4 mm e Sb na faixa de 24 a 162 s-1. A magnitude de Jg medida na 1ª e 2ª campanhas mostrou-se acima dos valores reportados pela literatura, indicando necessidade de modificação de condições operacionais dos equipamentos, assim como cuidadosa manutenção. Posteriormente, a 3ª campanha indicou maior conformidade dos parâmetros de dispersão de gás em relação à literatura, constatando-se uma considerável melhora de desempenho do processo de flotação.
Title in English
Gas dispersiom measurement in industrial mechanical cells and their conditions.
Keywords in English
Gas dispersion. Mechanical flotation cells. Superficial gas velocity. Bubble diameter. Bubble surface area flux
Abstract in English
The quality of gas dispersion within flotation cells is usually characterized by superficial gas velocity (Jg), gas hold-up (?g), bubble size distribution (db or D3,2) and bubble surface area flux (Sb). Because flotation is a separation process which depends largely on the interaction (collision + adhesion) of hydrophobic particles and air bubbles, process performance is dependent on appropriate gas dispersion within the slurry. Thus, this study aimed to characterize the gas dispersion of two flotation cells on a flotation bank composed of four 42.5 m³ Wemco cells (sub aerated), operating in series at the plant of Vale Fertilizantes (Cajati-SP). There were three measurement campaigns conducted under different operating conditions: a) Impeller diameter (D) of 1.09 m and impeller rotation speed (N) between 145 and 175 min-1; b) D = 0.99 m and 110 <= N <= 190 min-1; c) D = 0.99 m and N = 120 and 130 min-1. The following gas dispersion values were determined: 0.7 <= Jg <= 5.4 cm/s, 7 <= ?g <= 15%, 1.6 <= D3,2 <= 2.4 mm and Sb in the range of 24 to 162 s-1. The magnitude of Jg at 1st and 2nd campaigns showed to be higher than the values reported in literature, calling for modification of operational conditions of the equipments, as well as carefully maintenance. In addition, results from the 3rd campaign indicated values of gas dispersion parameters that matched those reported by current literature, accompanied by considerable mprovement in process performance.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.