Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2019.tde-12092019-135122
Document
Auteur
Nom complet
Leandro Souza Domingues
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2019
Directeur
Jury
Melo, Hercilio Gomes de (Président)
Ferrari, Jean Vicente
Magnabosco, Rodrigo
Titre en portugais
Estudo da eficiência de inibidores e da resistência à  corrosão localizada da superliga Incoloy 800, utilizada no circuito secundário do gerador de vapor do tipo PWR, em meio simulador de frestas.
Mots-clés en portugais
Cloreto
Corrosão
Etanolamina
Gerador de vapor
Incoloy 800
Inibidores de corrosão
Tiossulfato
Resumé en portugais
A liga Incoloy 800 é usada em tubulações do gerador de vapor (GV) nos reatores de água pressurizada (PWR). Nestes, os tubos são suportados por placas. A literatura tem reportado a ocorrência de falhas por corrosão por frestas na região onde os tubos entram em contato com as placas de suporte, atribuída ao acúmulo conjunto de cloreto (Cl-) e tiossulfato (S2O32-). Para minimizar este problema inibidores de corrosão são adicionados à água de alimentação. Apesar da corrosão por frestas ser o foco principal da literatura, os mecanismos por trás do efeito conjunto de ambos os íons agressivos sobre a resistência à corrosão localizada das superligas em conjunto com o efeito da presença de inibidores têm sido pouco abordados. Desse modo, o presente estudo utilizou técnicas eletroquímicas e de caracterização superficial para estudar o efeito da presença de S2O32- em diferentes concentrações e da adição de 10-6M do inibidor de corrosão etanolamina (ETA) sobre a resistência à corrosão por pite da superliga Incoloy 800 em meio 0,3M de Cl-. Os ensaios de espectroscopia de impedância eletroquímica (EIS) realizados no potencial de circuito aberto (OCP) mostraram que, para todas as condições utilizadas, a liga se mantém passiva, e que o comportamento melhora com a diminuição da razão [Cl-/S2O32-] e com o tempo de imersão. Para esta condição, as análises por XPS mostraram que a interação do Cl- com a camada passiva é fraca quando este íon se encontra isolado no meio e que o tiossulfato apresenta condições para a redução sobre a película passiva do Incoloy 800, ambos os fatores podendo ser responsáveis pela melhora da resposta de impedância com o tempo de imersão. O ajuste dos diagramas de impedância com circuitos equivalentes (CEE) evidenciou a adsorção de S2O32-, indicando que este íon controla a resposta de impedância em altas frequências quando adicionado em concentrações equivalentes à concentração de cloretos. Os ensaios de polarização anódica mostraram que o Incoloy 800 não é suscetível à corrosão localizada na presença apenas de tiossulfato, porém apresenta corrosão por pites em 0,3M de NaCl, exibindo, no entanto, propriedades de repassivação. Por sua vez, na solução contendo os dois ânions o comportamento eletroquímico é controlado pela razão [Cl-/S2O32-]. Assim para uma alta razão, a quebra da película se dá pela ação do cloreto com o tiossulfato atuando de modo a estabilizar os pites metaestáveis, diminuindo o potencial de quebra e impedindo a repassivação do eletrodo. Por sua vez, para uma baixa razão, o oxiânion atua de modo inibitivo, impedindo o efeito prejudicial do Cl- sobre a camada passiva. A caracterização por MEV mostrou que, sempre que ocorreu, a corrosão por pites teve início nas proximidades das partículas de segunda fase de TiN, e que a presença do tiossulfato aumenta a agressividade do ataque localizado, formando pites maiores e mais profundos, embora em menor número, provavelmente devido à formação de sulfetos metálicos nas regiões submetidas ao ataque localizado. No OCP, a adição de 10-6M de ETA ao meio contendo 0,3M de NaCl sem e com 0,075M de S2O32- provocou mudanças no potencial de corrosão e diminuiu o módulo de impedância da liga. As análises por XPS mostraram a adsorção da ETA à superfície do eletrodo e que este aumenta à adsorção do íon tiossulfato à superfície do eletrodo. Por sua vez, o ajuste dos diagramas de impedância com CEE indicou a ocorrência de processos controlados por difusão na camada passiva. Em concordância com os ensaios de impedância, as curvas de polarização anódica apresentaram maiores valores de corrente passiva na presença do inibidor. No que concerne à corrosão por pites, a adição de 10-6M de ETA não inibiu a quebra da película protetora para a solução contendo apenas íons cloreto e impediu a repassivação, levando à formação de pites maiores a mais profundos. Porém na presença de Cl- e S2O32- (em baixa concentração) houve inibição da quebra da película passiva, indicando um possível efeito sinergético entre a amina e o oxiânion no sentido de dificultar a adsorção dos íons cloreto.
Titre en anglais
Study of inhibition efficiency and localized corrosion resistance of Alloy 800, used in the secondary circuit of the PWR type steam generator, in a crevice simulator medium.
Mots-clés en anglais
Alloy 800
Chloride
Ethanolamine
Pitting corrosion
Steam generator
Thiosulfate
Resumé en anglais
Alloy 800 is used for tubing in the steam generator (SG) at Pressurized Water Reactors (PWR). These pipes are supported by plates. The literature reports the occurrence of crevice corrosion failures on the tubes in the regions where they are in contact to the supporting plates, which has been attributed to the accumulation of chloride (Cl-) and thiosulfate (S2O32-). In order to minimize this problem, corrosion inhibitors are added to the feed water. Despite crevice corrosion be the main focus of the literature, the mechanisms behind the joint effect of both aggressive ions on the localized corrosion resistance of superalloys in the presence of inhibitors have been scarcely investigated. Therefore, the present study used electrochemical and surface characterization techniques in order to study the effect of S2O32- presence in different concentrations and the addition of 10-6M of ethanolamine (ETA) corrosion inhibitor on the pitting corrosion resistance of Alloy 800 in 0.3M NaCl solution. The electrochemical impedance spectroscopy (EIS) tests performed at open circuit potential (OCP) showed, for all conditions applied, that the alloy maintains its passivity, which is enhanced as the [Cl-/S2O32-] ratio decreases as well as the immersion time. For this condition, the XPS analyses showed that Cl- ions interact weakly with the passive layer when they are the sole aggressive species in the medium and that thiosulfate may be reduced on the passive film of Alloy 800, both factors may explain the improvement of impedance response with the immersion time. EIS diagrams fitting with electrical equivalent circuits (EEC) pointed to S2O32- adsorption at the alloy surface, and indicated that these ions may control the high frequency impedance response when added at concentrations equivalent to that of chloride ions. Anodic polarization experiments showed that Alloy 800 is not susceptible to localized corrosion in the presence of only S2O32-, but exhibits pitting corrosion in 0.3M NaCl, showing, although, repassivation properties. On the other hand, in the medium containing both anions the electrochemical behavior is controlled by [Cl-/S2O32-] ratio. Thus, for a high ratio, chlorides breakdown the film and thiosulfate stabilize the metastable pits, reducing the breakdown potential and preventing the repassivation of the electrode. However, for a low ratio, the oxyanion acts as inhibitors, preventing the detrimental effect of Cl- on the passive layer. SEM characterization showed that, whenever it occurred, pitting corrosion starts at TiN second phase particles, and that the presence of thiosulfate enhances the aggressiveness of the localized attack, forming larger and deeper pits, but in a lesser quantity, probably due to the formation of metallic sulphides in regions submitted to the localized attack. On the OCP, the addition of 10-6M of ETA to the medium containing 0.3M NaCl with and without 0.075M S2O32- caused shifts on the corrosion potential and decreased the alloy impedance modulus. The XPS analyses showed the adsorption of ETA on the electrode surface and that it also enhances the thiosulfate adsorption. On the other hand, fitting of the EIS diagrams with EEC indicated the occurrence of diffusion-controlled processes within the passive layer. In agreement with the impedance experiments, the anodic polarization curves showed higher passive current values in the presence of inhibitor. With regard to pitting corrosion, the addition of 10-6M of ETA did not inhibit the breakdown of the passive film in the solution containing only chloride ions and also prevented the repassivation process, leading to the formation of larger and deeper pits. However, in the presence of Cl- and S2O32- (low concentration) the inhibition of the passive layer breakdown occurred, indicating a possible synergistic effect between the amine and the oxyanion in order to hindering the adsorption of chloride ions.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-09-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.