• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.3.2008.tde-11052009-172021
Documento
Autor
Nome completo
Carlos Humberto Sartori
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2008
Orientador
Banca examinadora
Tschiptschin, André Paulo (Presidente)
Boccalini Júnior, Mário
Pinedo, Carlos Eduardo
Título em português
Influência dos tratamentos térmicos e tratamentos criogênicos na tenacidade do aço rápido AISI M2.
Palavras-chave em português
Aço rápido
Tenacidade dos materiais
Tratamento térmico
Resumo em português
Neste trabalho foi avaliada a tenacidade do aço rápido AISI M2 tratado termicamente por rotas convencionais e rotas criogênicas. A tenacidade foi verificada através de ensaios de impacto em corpos de prova sem entalhe e ensaios de flexão 3 pontos em corpos de prova cilíndricos. Os tratamentos térmicos foram realizados em forno a vácuo com resfriamento por nitrogênio sob 6 bar de pressão. As rotas convencionais foram constituídas por austenitização, têmpera e triplo revenimento a 560°C. As rotas criogênicas foram constituídas por austenitização e têmpera similares às rotas convencionais, além de processamento criogênico em nitrogênio líquido por períodos de 2 horas, 24 horas e 48 horas. As amostras submetidas a 2 horas de criogenia após a têmpera sofreram somente um revenimento e as amostras submetidas a 24 e 48 horas de criogenia sofreram triplo revenimento, todos a 560°C. Buscando-se avaliar o efeito da quantidade de austenita retida nos resultados dos processos criogênicos, utilizaram-se três temperaturas de austenitização: 1180°C, 1200°C e 1220°C. A caracterização metalográfica das amostras foi feita através de recursos de microscopia óptica, microscopia eletrônica de varredura, EDS e difração de raios-X. Os resultados do ensaio de impacto e flexão 3 pontos mostram que as rotas criogênicas produziram microestruturas finais com tenacidade igual ou superior às rotas convencionais, com destaque especial às rotas criogênicas com somente um revenimento que apresentaram resultados superiores às rotas convencionais consagradas, com múltiplos revenimentos. A análise fractográfica revela quantidade superior de áreas de fratura dúctil nas amostras tratadas por rotas criogênicas quando comparadas às amostras tratadas por rotas convencionais. Através da análise metalográfica via microscopia eletrônica de varredura verificaramse poucas diferenças microestruturais entre as amostras tratadas com e sem criogenia. O teor de austenita retida nas amostras tratadas pelas rotas criogênicas (dentro da mesma temperatura de austenitização) é bastante semelhante porém é sensivelmente inferior às amostras tratadas por rotas convencionais. Verificou-se que existem divergências na literatura no que diz respeito aos carbonetos precipitados devido ao processo criogênico, principalmente em relação a suas dimensões e características. O condicionamento da martensita e a precipitação de carbonetos pôde ser demonstrado indiretamente através do deslocamento do pico de dureza secundária na curva de revenimento de amostras submetidas à criogenia após a têmpera. Os melhores resultados foram verificados nas amostras criogênicas austenitizadas a 1180°C, que apresentaram menor quantidade de austen ita retida após a têmpera, mostrando assim que os processos criogênicos atuam na martensita obtida na têmpera e que a temperatura de austenitização desempenha papel fundamental nos resultados dos processos criogênicos.
Título em inglês
Influence of the heat treatments and cryogenic treatments on the toughness of the AISI M2 high speed steel.
Palavras-chave em inglês
Cryogenic treatments
High speed steel
Toughness
Resumo em inglês
In this work the toughness of the AISI M2 high speed steel heat treated by conventional and cryogenic routes has been evaluated. The toughness was evaluated through un-notched impact samples and 3 points bending cylindrical samples. The heat treatments were carried out in a vacuum furnace using nitrogen quenching with 6 bar of pressure. The conventional routes were constituted by austenitizing, quenching and triple tempering at 560°C. The cryogenic routes were constituted by the same austenitizing and quenching parameters used for the conventional routes, and also by cryogenic processing in liquid nitrogen for 2 hours, 24 hours and 48 hours. The samples submitted to 2 hours of cryogenic processing after quenching received only one tempering and the samples submitted to 24 and 48 hours of cryogenic processing were triple tempered, all at 560°C. In order to check the effect of the amount of retained austenite on the cryogenic processes, three different austenitizing temperatures were used: 1180°C, 1200°C and 1220°C. The metallographic characterization was performed using optical microscopy, scanning electronic microscopy, EDS analysis and X-ray diffraction. The impact and 3 points bending tests results show that the cryogenic routes have produced final microstructures with toughness values equal or superior to the conventional routes with a special highlight to the cryogenic routes with only one tempering after the freezing process, that have shown superior results compared to the classic multi-tempering cycles. The fractographic analysis has revealed for the cryogenic routes samples a greater amount of ductile fracture areas compared to the conventional routes of hardening. The scanning electronic microscopy analysis has revealed few microstructure differences between the conventional and cryogenic hardening routes. The amount of retained austenite amongst the cryogenic samples (with the same austenitizing temperature) is similar, but is sensibly less than the amount found in the samples submitted to the conventional routes. Several divergences has been detected in the literature related to the cryogenic treatment of tool steels, especially concerning the dimensions and characteristics of the precipitated carbides. The martensite conditioning and the fine carbide precipitation could be indirectly demonstrated by the shift of the secondary hardness peak on the tempering curve of samples submitted to cryogenic treatment after the quenching. Optimum results were observed in the cryogenic samples hardened at 1180°C. Those samples retained the lowest amounts of austenite after quenching showing that the cryogenic processes has an effect in the quenching formed martensite and that the austenitizing temperature is a key factor on the final results of the cryogenic processes.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2009-07-06
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.