• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2011.tde-24082011-103123
Documento
Autor
Nombre completo
Carina Guimarães de Souza Melo
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2011
Director
Tribunal
Rodrigues, Antonio de Castro (Presidente)
Buzalaf, Marilia Afonso Rabelo
Matsumoto, Mariza Akemi
Título en portugués
Enxerto sintético e biológico, com e sem preenchimento de veia jugular externa, no reparo de nervo periférico em ratos
Palabras clave en portugués
Colágeno
Membranas
Nervo periférico
PLGA
Regeneração
Tubulização
Resumen en portugués
Apesar do desenvolvimento da tecnologia envolvendo o campo da regeneração em nervos periféricos, ainda não existe uma técnica para recuperação do tecido nervoso que apresente resultados totalmente satisfatórios, fato que desperta o interesse de vários pesquisadores em todo mundo e representa um desafio para os cirurgiões que realizam procedimentos reconstrutivos e estéticos. Embora o enxerto autólogo de nervo seja a melhor alternativa para a recuperação de nervos periféricos lesados, as técnicas que envolvem o reparo tubular têm alcançado excelentes resultados através da utilização de materiais sintéticos e biológicos, sob a forma de tubos, no reparo de extensos segmentos nervosos. Hoje, através dos avanços da engenharia tecidual, novos materiais estão em desenvolvimento, com o objetivo de aliar características microscópicas às técnicas cirúrgicas existentes. O colágeno, que é sabidamente um elemento promotor da proliferação celular e do reparo tecidual, tem sido amplamente utilizado em estudos de regeneração nervosa. Da mesma maneira, o ácido poli-láctico-poli-glicólico (PLGA), um copolímero sintético, tem apresentado algumas características favoráveis ao processo de regeneração, como biocompatibilidade e propriedades mecânicas adequadas. Com o propósito de facilitar a regeneração nervosa quando ocorre perda tecidual, uma técnica já difundida pode ser destacada: o enxerto de veia invertida, em que a veia jugular externa é utilizada ao avesso, funcionando como um tubo, criando um microambiente para a regeneração nervosa, através da exposição de elementos fundamentais da camada mais externa do vaso (túnica adventícia). Neste trabalho, agregamos como diferencial a utilização de dois tipos de membranas, especialmente desenvolvidas para fins odontológicos, que visam neoformação óssea, em um estudo que visa à regeneração de um nervo periférico misto, o nervo isquiático. As membranas de colágeno e PLGA foram colocadas na região do enxerto, sob a forma de tubo, com o objetivo de recuperar um segmento de 10 mm do nervo referido. E, por fim, aliamos a utilização de um segmento de 5 mm da veia jugular externa como tecido de preenchimento dos tubos feitos com as membranas, na tentativa de verificar a eficácia das moléculas biológicas presentes neste vaso, porém agora sendo utilizadas diretamente dentro do enxerto. Após um período de 6 semanas, o grupo que apresentou o melhor resultado foi aquele em que foi utilizada a membrana de colágeno, na forma de tubo, preenchida com a veia jugular externa. Nesse grupo, o diâmetro médio das fibras mielínicas apresentou um valor médio de 5,8 µm e espessura média da bainha de mielina de 1,65 µm. Para o período de 12 semanas, entre os grupos analisados, o maior valor médio encontrado para o diâmetro foi de 5,64 µm e 1,31 µm para a espessura, sendo que este resultado foi apresentado pelo grupo em que se utilizou a membrana de PLGA sem preenchimento com a veia jugular. Embora os valores não sejam muito inferiores, nos dois períodos, ficaram abaixo dos valores encontrados nos grupos controle normais. Em suma, acreditamos que as membranas de colágeno e PLGA, associadas à técnica de tubulização, apresentam grande potencial para serem utilizadas na regeneração de nervos periféricos.
Título en inglés
Syntetic and biological graft, filled with the external jugular vein in the repair of peripheral nerve in rats
Palabras clave en inglés
Collagen
Membranes
Peripheral nerve
PLGA
Regeneration
Tubulization
Resumen en inglés
Despite the development of technology involved in peripheral nerve regeneration, there is no technique that presents a recovery of the nervous tissue with completely satisfactory results. This fact arouses interest of several researchers around the word. Although the autologous nerve grafting is the current gold standard for the repair of large nerve gaps, over the past decades the development of artificial nerve conduits has therefore been of great interest due to the excellent results achieved. Through the advances in tissue engineering, new materials, synthetic and biological, have been used for construct nerve guides. The collagen is one of the oldest natural polymers used as a biomaterial, and it is known as a promoter of cell proliferation and of tissue repair. In the same way, the synthetic copolymer, poly lactic-co-glycolic acid (PLGA), have been used for nerve regeneration, and it have shown some favorable characteristics to nerve repair such as stability, biocompatibility, and mechanical properties. With the purpose of facilitating the regeneration in large nerve gaps, the inside-out vein graft is a widespread technique, where the vein works as a conduit, and it provides a good microenvironment for axon regeneration through the exposition of some primordial elements of its adventitial layer. In this work, we join as a differential the use of two materials, specially developed for dental purposes, which are normally used to facilitate the osteogenesis, in a nerve regeneration study. We performed the surgical procedures in the sciatic nerve, with two types of membranes (PLGA and collagen), which were used as tubes, in order to promote the regeneration of this nerve. The collagen and PLGA membranes were used with the objective of a recovery in a 10-mm sciatic nerve gap model. These tubular implants were filled with a 5 mm segment of the jugular vein in order to verify the effectiveness of some biological molecules of the adventitia layer in the nerve regeneration. After 6 and 12 weeks the graft and the distal stump were observed under light microscopy. In each studied period, the diameters of the myelin fibers, and the thickness of the myelin sheaths of the regenerated axons were measured. After 6 weeks, the group which presented the best result was the group with the collagen membrane tube filled with the external jugular vein. In this group the diameter of the myelin fibers presented an average value of 5.8 µm and an average value of the thickness of the myelin sheaths of 1.65 µm. After 12 weeks, between all the groups, the best results were found in the group where the PLGA membrane unfilled with the external jugular vein was used as a nerve guide, which presented the average diameter of 5.64 µm, and the average thickness of 1.31 µm. Although the average values werent much lower than the values found in the controls, they were beneath than the normal groups. These results proved that the collagen and the PLGA membranes have a great potential to be used as artificial nerve conduits for promoting peripheral nerve regeneration.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-08-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.