Efeito da variação dos parâmetros de potência e energia por pulso na resistência de união à dentina de sistema adesivo irradiado com laser de diodo
Palabras clave en portugués
Adesivos
Dentina
Lasers
Resistência à tração
Resumen en portugués
O uso do laser previamente à polimerização de sistemas adesivos aplicados sobre a dentina tem sido proposto para melhorar a resistência de união à dentina. O objetivo foi avaliar o efeito da variação da potência (P) e da energia por pulso (Ep) na resistência de união à dentina de um sistema adesivo convencional irradiado com laser previamente à fotoativação. Duzentos terceiros molares foram distribuídos aleatoriamente em 10 grupos (n=20) sendo um grupo sem irradiação (Controle) e nove grupos irradiados com laser de Diodo (970 nm) (SiroLaser - Sirona Dental Systems - Benshein, Alemanha), de acordo com a potência (P) e energia por pulso (Ep) utilizados: 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. Em todos os grupos fez-se o condicionamento com ácido fosfórico, aplicação do sistema adesivo convencional de dois passos AdperTM Single Bond 2 (3M ESPE, St Paul, MN, EUA) e restauração com resina composta Z250 (3M). Para avaliar a resistência de união foi realizado teste de microtração obtendo-se os valores em MPa. Os resultados foram analisados pelo ANOVA a dois critérios, seguido de Dunnett t (p < 0,001) para comparação entre os grupos. Os grupos irradiados foram avaliados pelo ANOVA a um critério, seguido dos testes de comparações múltiplas Bonferroni e Tamhane. Os valores de resistência de união ± desvio padrão de todos os grupos foram, respectivamente: 0 - Controle (34,60±10,76); 1 - (19,62±8,65); 2 - (27,56±9,20); 3 - (30,34±7,92); 4 - (23,31±5,96); 5 - (20,93±7,46); 6 - (24,67±8,59); 7 - (23,61±7,04); 8 - (25,94±6,82) e 9 - (21,48±3,59). O laser de Diodo influencia na resistência de união entre os grupos irradiados e não irradiado. A potência de 0,5W e energia por pulso de 0,1J influenciam positivamente nos valores de resistência de união quando o sistema adesivo é irradiado previamente a sua fotoativação.
Título en inglés
Effect of the variation of the parameters of output power and pulse energy on bond strength to dentin irradiated of conventional adhesive system with diode laser
Palabras clave en inglés
Adhesives
Dentin
Lasers
Tensile strength
Resumen en inglés
The use of the laser prior to polymerisation of adhesive systems applied to the dentin has been proposed to improve the bond strength of dentin. The aim of this study was to investigate the effect of the variation of the output power (P) and pulse energy (Ep) on bond strength to dentin irradiated of conventional adhesive system with laser. Two hundred third molars were randomly distributed in 10 groups (n = 20): a group without laser irradiation (group control) and nine groups irradiated with diode laser (970 nm) (SiroLaser Sirona Dental Systems-Benshein, Germany), according to the output power (P) and pulse energy (Ep): 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. It was used in all groups etching with phosphoric acid, application of conventional adhesive system AdperTM Single Bond 2 (3M ESPE, St. Paul, MN, USA) and restoration with composite resin Z250 (3M). Microtensile test was performed obtaining bond strength values in MPa. Results were analyzed by two-ways ANOVA test, followed by Dunnett t (p < 0.001) for comparison between groups. The groups laser irradiated were assessed by one-way ANOVA test and subsequent t test with Bonferroni and Tamhane corrections. Bond strength values ± standard deviation for the groups were, respectively: 0 group control (34.60 ± 10.76); 1 - (19.62 ± 8.65); 2 - (27.56 ± 9.20); 3 - (30.34 ± 7.92); 4 - (23.31 ± 5.96); 5 - (20.93 ± 7.46); 6 - (24.67 ± 8.59); 7 - (7.04 ± 23.61); 8 - (25.94 ± 6.82) and 9 - (3.59 ± 21.48). The Diode laser influences on bond strength between irradiated and without irradiated groups. The output power 0.5W and energy per pulse 0.1J influence positively in the bond strength values when the adhesive system is irradiated prior to their light curing.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-04-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.