• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.25.2012.tde-05112012-181419
Document
Author
Full name
Flávia Pardo Salata Nahsan
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2012
Supervisor
Committee
Mondelli, Rafael Francisco Lia (President)
Bresciani, Eduardo
Duarte, Marco Antonio Hungaro
Naufel, Fabiana Scarparo
Wang, Linda
Title in Portuguese
Avaliação da influência da aplicação de um selante de superfície no comportamento clínico de restaurações de resina composta classe I
Keywords in Portuguese
Resinas compostas
Selantes dentários
USPHS
Abstract in Portuguese
A aplicação de selantes de superfície, através da penetração nas irregularidades superficiais e na interface dente/restauração, é realizada ao final do procedimento restaurador e pode minimizar algumas limitações, prolongando a longevidade clínica das restaurações de resina composta. Este estudo clinico randomizado se propôs a avaliar o efeito da aplicação de um selante de superfície no comportamento clínico de restaurações posteriores de resina composta do tipo classe I. Vinte e sete pares de dentes molares ou pré-molares, superiores ou inferiores, que apresentavam lesões de cárie (classe I) ou restaurações de amálgama ou resina composta (classe I) insatisfatórias, que necessitavam de substituição completa, foram aleatorizados e preparados e restaurados com a resina composta Esthet-X. Sobre a superfície da resina de apenas um dente de cada par foi aplicado o selante de superfície Lasting Touch utilizando o modelo experimental de boca dividida. A avaliação única foi realizada empregando-se o método direto USHPS modificado, nos tempos: baseline, 6 meses, 12 meses, por dois operadores. Radiografias interproximais e réplicas das faces oclusais foram obtidas por meio da moldagem com silicona de adição e vazadas com resina epóxica para avaliação qualitativa com Microscópio Eletrônico de Varredura. Os dados foram submetidos ao teste de Mc Nemar (p<0,05). Para a integridade marginal, após 6 meses de avaliação, apenas 1 (4%) restauração do grupo com selante de superfície recebeu o escore Bravo. Aos 12 meses, a integridade marginal apresentou 1 (4%) do grupo sem selante e 2 (7%) restaurações com selante com escore Bravo. Os resultado apresentados nos períodos de avaliação não apresentaram diferenças estatisticamente significantes (p=1,0, para todas as condições. Não houve diferença no desempenho clínico de restaurações de resina composta com e sem selante de superfície, sendo aceitáveis após 12 meses de avaliação. As observações em MEV demonstraram que aplicação do selante de superfície promove superfícies mais lisas e regulares para todos os tempos avaliados. Em um período de 12 meses, o selante de superfície mostrou estabilidade na condição avaliada. O Mev, entretanto, não demonstrou superioridade ao grupo sem a aplicação de selante de superfície (controle).
Title in English
Evaluation of the influence of a surface sealant in the clinical behavior of composite resin class I restorations
Keywords in English
Resin composites
Surface penetrating sealant
USPHS
Abstract in English
The finishing, polishing and surface sealant application, by superficial irregular penetration and between restoration interface, are applied at the end of the restoration and decrease these limitations, and extend the clinical longevity of composite resin restorations. This clinical randomized controled study however aimed to evaluate the effect of the surface sealant application in the clinical behavior of composite posterior resin class I restorations. Twenty seven pairs of upper or lower molars or premolars with carious lesions (class I), and unsatisfactory amalgam or composite resin restorations, which needed total replacement, were randomized and prepared and restored with Esthet X composite resin. The composite resin surface of one tooth from each pair was covered with Lasting Touch surface sealant (Split Mouth Design). The clinical evaluation was made by using the modified direct method USPHS, at the following times: baseline, 6 months and 12 months, by two different operators. Bitewing radiographs and replicas of the occlusal surfaces were obtained by using a silicone impression material poured with epoxy resin for the qualitative evaluation with Scanning Electron Microscopy. The data was analyzed with the McNemar test (p <0.05). Results showed that for the marginal integrity, after 6-month evaluation, only 1 (4%) sealed restoration had a Bravo rating. At the end of 12 months, the marginal integrity showed 1 (4%) sealed restoration and 2 (7%) non sealed Bravo restorations. Results at all evaluations periods did not show statistical significant differences (p=1.0) for all conditions. There was no difference in the clinical performance of the composite resin restorations (Esthet X) with or without the surface sealant (Lasting Touch), demonstrated good behavior after 12 months. Based on SEM examinations, the surface sealant application promoted a regular and smooth surface, for all the evaluation times. In a 12 months evaluations period, the surface sealant demonstrated stability at the evaluated condition. The SEM, however, did not presented better conditions in the no sealant application group (control).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-11-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.