Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2016.tde-02022016-132909
Documento
Autor
Nombre completo
Marlyni Aparecida Zens
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2015
Director
Tribunal
Francisconi, Paulo Afonso Silveira (Presidente)
Borges, Ana Flávia Sanches
Lisboa Filho, Paulo Noronha
Título en portugués
Avaliação do tratamento de superfície por sonoquímica na resistência de união entre zirconia tetragonal policristalina estabilizada por ítria e cimento resinoso
Palabras clave en portugués
Microcisalhamento
Tratamento de superfície
Y-TZP
Resumen en portugués
O objetivo deste estudo foi avaliar o efeito do tratamento ultrassônico como tratamento de superfície da zircônia tetragonal policristalina estabilizada por ítria (YTZP) e depois da sinterização final, por meio de mensuração da rugosidade superficial e teste de resistência adesiva por microsisalhamento. Para tanto, discos de Y-TZP foram confeccionados e distribuídos em 4 grupos (n=7), conforme o tratamento de superfície: 1-PRE: sonicação pré-sinterização; 2-POS: sonicação póssinterização; 3-JAT: jateamento com partículas óxido de alumínio 50μm; 4-CON: sem tratamento. Os espécimes foram polidos e padronizados e posteriormente submetidos aos tratamentos de acordo com cada grupo. Os grupos POS, JAT e COM foram sinterizados previamente ao tratamento e o grupo PRE após a sonicação. Os grupos PRE e POS foram submetidos a tratamento em processador ultrassonico (Sonics VCX-750) em potência nominal de 30% durante 15 minutos. O grupo JAT foi jateado com partículas de alumínio 50μm a uma distância de 15 cm, enquanto o grupo CON não recebeu nenhum tratamento. A mensuração de rugosidade superficial média (Ra) foi feita em Microscópio Confocal (MC), em seguida cilindros de cimento resinoso foram preparados e fotoativados na superfície do Y-TZP para serem submetidos ao ensaio mecânico de microcisalhamento realizado em máquina de ensaios universal (INSTRON). Os valores de rugosidade superficial e resistência de união obtidos foram submetidos a ANOVA a um critério e teste de Tukey. Quanto aos valores de rugosidade superficial, o grupo PRE (299,91 Mpa) e POS (291,23 Mpa) não apresentaram diferença estatística significante e o grupo JAT (925,21 Mpa) mostrou maiores valores de rugosidade superficial quando comparado ao PRE e POS. Para o teste de microcisalhamento não foram observadas diferenças estatisticamente significantes entre os grupos. Por meio dos resultados obtidos foi possível observar que o tratamento ultrassonico é capaz de alterar a superfície da Y-TZP e influenciar na resistência adesiva ao cimento resinoso.
Título en inglés
Evaluation of surface treatment by sonochemical the bond strength between Yttria-Stabilized Tetragonal Zirconia Polycrystals and resin cement
Palabras clave en inglés
Microshear
Surface treatment
Y-TZP
Resumen en inglés
The objective of this study was to evaluate the effect of ultrasonic treatment as surface treatment of Y-TZP before and after the final sintering, through measurement of surface roughness and bond strength by microshear test. Therefore, Y-TZP discs were made and distributed in 4 groups (n = 7), as surface treatment: 1-PRE: Presintering sonication; 2-POS: Post-sintering sonication; 3-JAT: air abrasion with aluminum oxide particles 50μm; 4-CON: no treatment. The specimens were polished and standardized and subsequently submitted to the treatments according to each group. The POS, JAT and CON groups been previously sintered to treatment and the PRE group after sonication. The PRE and POS groups were submitted to Ultrasonic Processor treatment (Sonics VCX-750) at 30% power for 15 minutes. The JAT group received air abrasion with aluminum particles 50μm at distance of 15 cm, while group received no treatment. The measurement of surface roughness was made in Confocal Microscope (MC), then resin cement cylinders were prepared and polymerized in Y-TZP surface to be subjected to mechanical testing microshear performed on universal testing machine (INSTRON). The values of surface roughness and bond strength were subjected to ANOVA and Tukey testAbout the values of surface roughness, the PRE group (299.91 MPa) and POS (291.23 MPa) showed no statistically significant difference and the JAT group (925.21 MPa) showed higher surface roughness values when compared to PRE and POS. For icroshear test statistically significant differences were observed between the groups. Through the results it was observed that the ultrasonic treatment is able to change the surface of the Y-TZP and influence the bond strength to resin cement.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.