• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2019.tde-14052019-172417
Documento
Autor
Nombre completo
Clara Fassoni Bonachela
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2018
Director
Tribunal
Valle, Accacio Lins do (Presidente)
Rubo, Jose Henrique
Santiago Junior, Joel Ferreira
Segalla, Jose Claudio Martins
Título en portugués
Resistência à tração entre componentes de pilar híbrido Conexão® submetido a teste de fadiga termomecânica
Palabras clave en portugués
Estresse mecânico
Implante dentário
Resistência à tração
Resumen en portugués
Os pilares de próteses sobre implantes são determinantes para o sucesso final da restauração. Dentre os mais variados disponíveis no mercado, os pilares híbridos são uma proposta atual que propõe associar otimização da estética com performance biomecânica de qualidade à longo prazo. Sendo assim, o objetivo desse estudo foi verificar a resistência à tração entre os componentes do pilar híbrido parafusado Precision Link® (Conexão®) após ensaio de fadiga térmica e mecânica, através de uma metodologia inovadora proposta pelos autores. Foram utilizados 33 Conjuntos Precision Link 3,5 NP + Coping de Zircônia Base para Acrescentar 3,5 (Conexão), distribuídos em 3 grupos de 11 espécimes, nomeados de acordo com o número de ciclos mecânicos aos quais foram submetidos durante o teste de fadiga (Grupo Controle [G CONTROLE], Grupo de 240 000 ciclos [G1] e Grupo de 480 000 ciclos [G2]). Após o ensaio de fadiga termomecânica, os pilares foram submetidos a teste de tração, por meio de um dispositivo desenvolvido exclusivamente para esse trabalho, adaptado em uma máquina de ensaios universal. Os dados de resistência a tração foram submetidos à análise estatística através da análise de variância a 1 critério e Teste de Tukey para comparações individuais, mediante à qual foi identificada diferença estatisticamente significativa entre G1 e G CONTROLE e G1 e G2, tendo G1 demonstrado valores de resistência a tração menores que os outros grupos (Valores médios: G CONTROLE= 58,172 N, G1= 46,181 N, G2= 64,725 N). Pode-se concluir que a metodologia proposta para esse estudo, com o desenvolvimento de um dispositivo específico de tração é efetiva para identificar os valores de resistência à tração dos componentes de pilares híbridos parafusados Precision Link® (Conexão®) e a exposição aos ciclos termomecânicos testados no ensaio de fadiga influencia nos valores de tração entre os mesmos, primeiro diminuindo-os e depois aumentando-os de volta possivelmente por conta do fenômeno de degradação em baixa temperatura nos componentes de zircônia.
Título en inglés
Tension strength between the two pieces of the hybrid abutment Conexão® after thermomechanical fatigue test
Palabras clave en inglés
Dental implant-abutment design
Mechanical stress
Tensile strength
Resumen en inglés
Implant abutments have a key role in the success of dental reabilitations. Among other options, hybrid abutments are a new option that can associate esthetic achievements with efficient long-term biomechanical performance. The purpose of this study was to verify the tension strenght between the components of the screw-retained hybrid abutment Precision Link® (Conexão®) after thermomechanical fatigue test, using an innovative approach. Thirty-three samples of Precision Link (d)3,5 NP + Zirconia Coping Add Base (d)3,5 (Conexão) were divided in three groups of eleven specimens each. The groups were divided by the number of mechanical cycles (Control Group [CONTROL G], Group of 240 000 cycles [G1] and Group of 480 000 cycles [G2]). After the thermomechanical fatigue test, the abutments were submitted to a tension strenght test in a specific device designed by the authors for this study. The referred device was coupled to an universal testing machine. Statistic analysis (ANOVA-1 e Tukey Test) showed G1 had statistical significative lower values of tension strenght than CONTROL G and also than G2. (Mean values: CONTROL G= 58,172 N, G1= 46,181 N, G2= 64,725 N) In conclusion, the methodology proposed for this study was effective in identifying the tension strenght values between the components of the screw-retained hybrid abutment Precision Link® (Conexão®). Also, the thermomechanical fatigue test influenced in the tension strenght values, first reducing the values of tension strenght, then increasing them back, by the transformation of phase of zirconia exposed to a wet environement.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-05-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.