• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2016.tde-07112016-085937
Documento
Autor
Nombre completo
Janaina Gomes Maciel
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2016
Director
Tribunal
Neppelenbroek, Karin Hermana (Presidente)
Oliveira, Pedro Cesar Garcia de
Pegoraro, Thiago Amadei
Santiago Junior, Joel Ferreira
Título en portugués
Padronização da metodologia para análise de sorção de água e solubilidade de materiais resilientes temporários para  base de prótese
Palabras clave en portugués
Absorção
Reembasadores de dentadura
Solubilidade
Resumen en portugués
Não existem normas internacionais que determinem limites aceitáveis de sorção de água e solubilidade para os materiais resilientes temporários para base de prótese, além de haver divergências metodológicas nos estudos. Objetivou-se avaliar de forma padronizada essas propriedades físicas para materiais macios de curta duração ao longo de sua vida útil. Corpos de prova (50mm x 0,5mm/ ISO-10139-2) de 7 condicionadores teciduais (Coe-Comfort-CC, Softone-ST, Rite-Line-RL, Dura Conditioner-DC, Hydro-Cast-HC, DentusoftDS e Visco-gel-VG) e 2 reembasadores resilientes temporários (Trusoft-TS e Coe-Soft-CS) foram individualmente confeccionados e submetidos à dessorção até estabilização das massas. Então, foram imersos em água destilada a 37oC por 3, 5, 7 ou 14 dias (n=10) para depois serem pesados, dessecados e pesados novamente. Os dados foram obtidos em porcentagens de sorção/solubilidade e analisados estatisticamente por ANOVA 2 fatores e teste de Tukey HSD (α=0,05). Em todos os períodos, VG (12,06±0,93 a 16,62±0,87%) apresentou a maior sorção de água dentre os materiais testados, sendo as menores porcentagens observadas para CC (2,23±0,53 a 2,99±0,49%) (P<0,05). CC, CS e TS não apresentaram alteração significativa da sorção de água ao longo de 14 dias (P>0,05). Já os demais materiais exibiram um aumento significativo da sorção de água entre os períodos de 7 e 14 dias (P<0,05). Para a solubilidade, valores médios inferiores e estatisticamente semelhantes foram apresentados pelos materiais DC, HC, DS, TS, RT e CS (0,28±0,30 a 2,13±0,23%) (P>0,05). ST (4,09±1,60 a 8,80±1,15%) demonstrou maior solubilidade que CC (1,89±0,30 a 3,35±0,70%), mas os mais altos valores percentuais dentre os materiais testados foram observados para VG (20,30±4,26 a 23,59±20,24%) (P<0,05). CC, DC, DS, HC, RT, TS e CS não apresentaram alterações na solubilidade percentual média ao longo dos 14 dias de avaliação. Já os condicionadores teciduais VG e ST exibiram aumento dos valores médios apenas aos 14 dias de imersão em água. Conclui-se que, ao longo da vida útil média de um condicionador tecidual (7 dias), os materiais CC, DC, HC, DS, RL, CS e TS apresentaram comportamento in vitro satisfatório em relação à sorção de água e solubilidade. De acordo com os resultados obtidos, os materiais CC, TS e CS foram considerados os mais indicados dentre os testados para reembasamento de próteses em até 14 dias.
Título en inglés
Standardization of methodology for water sorption and solubility analysis of temporary resilient denture liners
Palabras clave en inglés
Denture liners
Solubility
Sorption
Resumen en inglés
There are no international standards that determine acceptable limits of water sorption and solubility for the temporary resilient liners, besides the differences in the methodology of the studies. It was aimed to evaluate in a standardized manner these physical properties of short-term soft materials throughout their lifespan. Specimens (50mm x 0.5mm/ ISO-10139-2) of 7 tissue conditioners (Coe-Comfort-CC, Softone- ST, Rite-Line-RL, Dura Conditioner-DC, Hydrocast-HC, Dentusoft-DS and Visco-gel- VG) and 2 temporary resilient liner (Trusoft-TS e Coe-Soft-CS) were individually prepared and submitted to desorption until mass stabilization. Afterwards, they were immersed in distilled water at 37oC for 3, 5, 7, or 14 days (n=10) to then be weighed, dried and reweighed. The data were obtained in percentages of sorption/solubility and statistically analyzed by 2-way ANOVA and Tukeys test (α=0.05). In all periods, VG (12.06±0.93 to 16.62±0.87%) showed the highest water sorption among the tested materials, with the lowest percentages observed for CC (2.23±0.53 to 2.99±0.49%) (P<0.05). CC, CS and TS showed no significant changes in water sorption over 14 days (P>0.05). The other materials exhibited a significant increase in water sorption between the periods of 7 and 14 days (P<0.05). For the solubility, lower (and statistically similar to each other) values were presented by DC, HC, DS, TS, RT, and CS materials (0.28±0.30 to 2.13±0.23%) (P>0.05). ST (4.09±1.60 to 8.80±1.15%) showed higher solubility than CC (1.89±0.30 to 3.35± 0,70%), but the highest percentages among tested materials were observed for VG (20.30±4.26 to 23.59±20.24%) (P<0.05). CC, DC, DS, HC, RT, TS, and CS showed no changes in the mean percentage solubility throughout the 14-day trial. The tissue conditioners VG and ST exhibited increased average values only at 14 days of water immersion. It was concluded that, over the lifespan of a tissue conditioner (7 days), the materials CC, DC, HC, DS, RL, CS, and TS presented suitable in vitro performance with respect to water sorption and solubility. According to the results, the materials CC, TS, and CS were considered best suited among the tested materials for denture relining of up to 14 days.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
JanainaGomesMaciel.pdf (743.56 Kbytes)
Fecha de Publicación
2016-11-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.