• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.25.2011.tde-25072011-165022
Documento
Autor
Nome completo
Daniel Salvatore de Freitas
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Bauru, 2011
Orientador
Banca examinadora
Janson, Guilherme dos Reis Pereira (Presidente)
Gandelmann, Italo Honorato Alfredo
Henriques, Rafael Pinelli
Título em português
Avaliação da variabilidade do ângulo nasolabial em repouso e sorrindo em pacientes com oclusão normal e harmonia facial
Palavras-chave em português
Cefalometria
Harmonia facial
Oclusão dentária
Resumo em português
Devido à incompatibilidade entre as medidas cefalométricas e a análise facial de alguns casos de retrusão de maxila, e a ausência de estudos que indiquem essa variação e sua implicação no diagnóstico e tratamento dos pacientes, o objetivo desta pesquisa foi determinar: a média e o desvio padrão do ângulo nasolabial (ANL) e da medida linear Prn-A em repouso e sorrindo e a diferença entre sorriso e repouso, em indivíduos com oclusão normal e harmonia facial, além de avaliar a presença de dimorfismo sexual. A amostra constituiu-se de 40 participantes brasileiros, sendo 20 de cada sexo, leucodermas, de faixa etária de 20 a 30 anos de idade, com oclusão normal, perfil facial agradável e harmonia facial. Foram analisadas, nas fotografias de perfil em repouso e sorrindo, com uma régua milimetrada à frente do perfil, e com a utilização do programa Dolphin, as medidas ANL e Prn-A. A análise estatística incluiu a estatística descritiva, testes t dependentes para comparar as variáveis em repouso e sorrindo, e testes t independentes para avaliar o dimorfismo sexual. Como resultados, observou-se que: a média do ANL em repouso foi de 104,93º, com desvio padrão de 8,04, e sorrindo, foi de 110,67º, com desvio padrão de 9,01, sendo que a diferença entre eles foi estatisticamente significante, com média 5,74º e desvio de padrão de 4,11. A média da variável linear Prn-A em repouso foi de 23,25mm, com desvio padrão de 1,95, e sorrindo, foi de 24,04mm, com desvio padrão de 2,07, sendo que a diferença entre eles foi estatisticamente significante, com média 0,79mm e desvio de padrão de 0,65. Não houve dimorfismo sexual para o ANL. A medida Prn-A em repouso e sorrindo se mostrou maior para o sexo masculino quando comparado ao sexo feminino.
Título em inglês
Evaluation of the variability of the nasolabial Angle in rest and smiling in patients with normal occlusion and facial harmony
Palavras-chave em inglês
Cephalometry
Dental occlusion
Facial harmony
Resumo em inglês
Due to the incompatibility of the cephalometric measurements and the facial analysis in some cases of maxillary retrusion, and the absence of studies that indicate this variation and implication in diagnosis and treatment of the patients, the objective of this study was to determine: the mean and standard deviation of the nasolabial angle (NLA) and the linear measure Prn-A during rest and smile and the difference between smile and rest, in subjects with normal occlusion and facial harmony, besides of evaluating the presence of sexual dimorphism. The sample comprised 40 Brazilian subjects, 20 of each sex, leucoderms, aging from 20 to 30 years, with normal occlusion, pleasant facial profile and facial harmony. It was analyzed, in profile photographs in rest and during smile, with a millimeter ruler in front of the profile, and using the Dolphin software, the measures NLA and Prn-A. The statistical analysis included descriptive statistics and dependent t tests to compare the rest and smiling variables and independent t tests to evaluate sexual dimorphism. As results, it was observed that: the mean of the NLA in rest was 104,93º, with a standard deviation of 8,04, and during smile, it was of 110,67º, with standard deviation of 9,01, and the difference between them was statistically significant, with mean of 5,74º and standard deviation of 4,11. The mean of the linear variable Prn-A in rest was of 23,25mm, with standard deviation of 1,95, and during smile, it was of 24,04mm, with standard deviation of 2,07, and the difference between them was statistically significant, with mean of 0,79mm and standard deviation of 0,65. There was no sexual dimorphism for the NLA. The measure Prn-A in rest and during smile showed greater for the males, when compared to females.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2011-07-27
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.