• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.25.2011.tde-18012012-102558
Documento
Autor
Nome completo
Thais Maria Freire Fernandes
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Bauru, 2011
Orientador
Banca examinadora
Henriques, Jose Fernando Castanha (Presidente)
Capelozza, Ana Lucia Alvares
Carreira, Daniela Gamba Garib
Navarro, Paula Vanessa Pedron Oltramari
Pedrin, Renata Rodrigues de Almeida
Título em português
Precisão e acurácia de medidas lineares da mandíbula em imagens 3D obtidas por meio da tomografia computadorizada de feixe cônico
Palavras-chave em português
Mandíbula
Ortodontia
Tomografia computadorizada de feixe cônico
Resumo em português
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula por meio da Tomografia Computadorizada de Feixe Cônico (TCFC), alterando o valor do voxel. Material e Métodos: Dez mandíbulas foram submetidas à TCFC seguindo dois protocolos de voxel, 0,2 e 0,4 mm, do aparelho i-CAT Classic. Dez medidas lineares foram realizadas 2 vezes, por 2 examinadores independentes, previamente calibrados, nos cortes multiplanares e nas reformatações 3D no programa Dolphin®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse e o teste de Bland-Altman foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Excelente precisão intra e boa precisão interexaminadores foi encontrada para todas as variáveis, com exceção da largura interforame mentual entre os dois examinadores nas reformatação 3D. As mensurações realizadas nos cortes multiplanares apresentaram maior acurácia que as mensurações nas reformatações 3D, em relação às medidas físicas. Conclusão: As imagens nos cortes multiplanares em TCFC nos dois protocolos de voxel podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares quando comparadas com às medidas físicas. Maior cautela deve ser tomada para as reformatações 3D, pois as mensurações neste formato foram precisas, mas não acuradas para todas as variáveis. Um protocolo com menor exposição aos raios X, sem comprometer o diagnóstico, torna-se viável, pois o aumento na resolução das imagens não aumenta a precisão e acurácia na mensuração das medidas lineares avaliadas.
Título em inglês
Accuracy and reliability of mandibular linear measurements on 3D CBCT images with different voxel sizes
Palavras-chave em inglês
Cone-beam computed tomography
Mandible
Orthodontics
Resumo em inglês
Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different voxel sizes. Methods: Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®, independently, by two operators twice. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) and BlandAltman were used for evaluating accuracy and reliability(p<0.05). Results: Excellent intrarater and good interobserver reliability values were found for linear measurements from CBCT images, with only one exception, interforame width, between observers in volume rendering images. Measurements performed on multiplanar reconstructed images were more accurate than the measurements in volume rendering compared to the gold standard. Conclusion: Linear measurements on multiplanar images of 0.2 and 0.4-voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. A protocol with less exposure, without compromising the diagnosis becomes feasible, because an increased voxel resolution did not result in greater accuracy of the measurements and potentially provides increased patient radiation exposure.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2012-01-19
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.