Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2017.tde-29092017-143119
Document
Auteur
Nom complet
Alana Ribeiro de Melo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2017
Directeur
Jury
Alvarenga, Katia de Freitas (Président)
Agra, Sandra Elisa Rossetto
Feniman, Mariza Ribeiro
Martins, Carlos Henrique Ferreira
Titre en portugais
Padrão de análise da timpanometria com sonda de 226 Hz na criança considerando a pressão do pico de máxima compliância e a compliância estática
Mots-clés en portugais
Complacência
Orelha média
Testes de impedância acústica
Resumé en portugais
A análise precisa dos resultados da timpanometria é essencial para determinar a condição da orelha média, principalmente em crianças nos primeiros anos de vida. Assim, o objetivo deste estudo foi apresentar um padrão de análise da timpanometria com sonda de 226 Hz para a faixa etária de seis meses a três anos, considerando a pressão do pico de máxima compliância e a compliância estática. Foram analisados prontuários de crianças de seis meses a três anos de idade atendidas no período de outubro de 2012 a fevereiro de 2016 no Centro de Pesquisas Audiológicas - Seção de Implante Coclear do Hospital de Reabilitação de Anomalias Craniofaciais e na Clínica de Audiologia Infantil da Clínica de Fonoaudiologia da Faculdade de Odontologia de Bauru, ambos da Universidade de São Paulo. A casuística foi dividida em dois grupos: grupo sem alteração de orelha média, composto por 224 orelhas, e o grupo com alteração de orelha média, composto por 59 orelhas. Foram considerados para análise os valores de pressão do pico de máxima compliância (daPa) e de compliância estática (ml) obtidos na timpanometria com sonda de 226Hz. No grupo sem alteração, o Teste Correlação Mann Whitney revelou que não houve diferença significante entre os sexos para pressão do pico de máxima compliância (p=0,782) e para a compliância estática (p=0,085). Também não houve correlação dos valores de pressão (p=0,678) e compliância (p=0,079) com a idade, de acordo com o Teste Correlação de Spearman. Considerando o intervalo entre os percentis 2,5 e 97,5 obtidos para a pressão e compliância nos grupos sem e com alteração, observou-se uma faixa de valores comum aos dois grupos, ou seja, os valores contidos nesta faixa não conseguiram classificar a orelha média como normal ou alterada. De acordo com os percentis 2,5 e 97,5, foi possível estabelecer uma faixa de normalidade para a pressão do pico de máxima compliância, de +52 daPa a -100 daPa, e para compliância estática, de 0,20 ml a 0,68 ml. Enquanto que na faixa de alteração, os valores variaram de -259 a 17,52 daPa para pressão e de 0,04 a 0,41 ml para a compliância. Assim, uma faixa de intersecção foi identificada, correspondente ao intervalo de -100 a 17,52 daPa para pressão do pico de máxima compliância e de 0,2 a 0,41 ml para a compliância estática. A análise dos dados demonstrou que a timpanometria com sonda de 226 Hz apresentou alta sensibilidade e baixa especificidade na faixa etária de seis meses a três anos.
Titre en anglais
Tympanometry analysis standard with 226 Hz of age six months to three years considering the pressure of the peak of maximum compliance and the static compliance
Mots-clés en anglais
Acoustic impedance tests
Compliance
Middle ear
Resumé en anglais
Accurate analysis of tympanometry results is essential to determine the condition of the middle ear, especially in children in their first years of life. Thus, this study aimed at presenting a standard analysis of tympanometry with a 226 Hz probe for the age range six months to three years, taking into account the pressure of the peak of maximum compliance and static compliance. The records of 6-month to three-year old children assisted from October 2012 to February 2016 at the Audiology Research Center - Cochlear Implant Section of the Craniofacial Anomalies Rehabilitation Hospital and at the Children's Audiology Clinic of the Audiology and Speech-Language Pathology Clinic of the Bauru Dentistry School, both of the University of São Paulo, were analyzed. The sample was divided into two groups: a group with no middle ear alteration comprising 224 ears and the group with middle ear alteration composed of 59 ears. For analysis, the pressure values of the maximum compliance peak (daPa) and static compliance (ml) obtained in the tympanometry with a 226Hz probe were considered. In the group with no alteration, the Mann Whitney Correlation Test showed no significant difference between the genders for the maximum compliance peak pressure (p = 0.782) and for static compliance (p = 0.085). No difference was seen, either, for pressure (p = 0.678) and compliance (p = 0.079) values, according to age, by using the Spearman Correlation Test. Considering the interval between percentiles 2,5 and 97,5 obtained for pressure and compliance in the groups without and with alteration, a range of values common for the two groups was observed, that is, the values contained in this range could not classify the Middle ear as normal or altered. According to percentiles 2,5 and 97,5, it was possible to establish a range of normality for the pressure of the maximum compliance peak, from +52 daPa to -100 daPa, and for static compliance, from 0.20 ml to 0.68 ml, while in the alteration range, values ranged from -259 to 17,52 daPa for pressure and from 0,04 to 0,41 ml for compliance. Thus, an intersection range was identified, corresponding to the interval of -100 to 17,52 daPa for the pressure of the maximum compliance peak and 0,2 to 0,41 ml for the static compliance. Data analysis showed that tympanometry with a 226 Hz probe presented high sensitivity and low specificity in the 6-month to 3-year age range.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-10-03
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.