• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2011.tde-27092011-152118
Documento
Autor
Nombre completo
Ademir Antonio Comerlatto Junior
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2011
Director
Tribunal
Costa Filho, Orozimbo Alves (Presidente)
Balen, Sheila Andreoli
Lamonica, Dionisia Aparecida Cusin
Título en portugués
Resolução temporal auditiva de crianças usuárias de implante coclear
Palabras clave en portugués
Criança
Implante coclear
Perda auditiva
Testes auditivos
Resumen en portugués
A resolução temporal auditiva é considerada uma das habilidades mais importantes para o processamento do sinal acústico ao longo do tempo. Ela permite identificar diferenças finas dos aspectos segmentais da fala, como a identificação de fonemas, e o início e o final de palavras em frases encadeadas. Crianças usuárias de Implante Coclear (IC) apresentam características próprias de decodificação e processamento do sinal da fala ao longo do tempo, realizada pelo IC. Diante do exposto, esta pesquisa teve por objetivo verificar o desempenho de crianças usuárias de IC em tarefas de resolução temporal. A amostra foi composta por 20 crianças usuárias de IC Nucleus 24/SPRINT (Grupo Experimental - GE) e 20 crianças sem alterações auditivas (Grupo Controle - GC). Foram aplicados o Random Gap Detection Test (RGDT) e o teste Gaps In Noise (GIN) para avaliar a habilidade de resolução temporal por meio de tarefas de detecção de gap. Os testes foram aplicados em campo livre e a 40dBNS. Os testes estatísticos utilizados para a análise dos dados foram o teste t de Student para dados independentes, e o teste de Mann Whitney e o Coeficiente de Correlação de Pearson. As crianças usuárias de IC obtiveram limiares de gap no RGDT de 74,13±51 ms e no teste GIN de 12,12±2,53 ms, sendo que apenas quatro das 20 crianças realizaram o teste GIN. Os limiares de gap do GC foram de 18,77±12,29 ms no RGDT e de 6,13±1,27 ms no teste GIN. A diferença entre os dois grupos foi estatisticamente significante. Além disso, houve diferença significativa na comparação dos resultados dos testes entre os sexos do GE, sendo o masculino melhor que o feminino. Não houve correlação entre a idade e os limiares de detecção de gap em ambos os grupos e, também, não houve significância entre o tempo de uso de IC e os resultados nos testes no GE. Mesmo avaliando a mesma habilidade auditiva, não houve correlação significante entre os resultados dos testes aplicados. Foi observado que crianças usuárias de IC apresentam os limiares de detecção de gap significativamente maiores que crianças sem alterações auditivas.
Título en inglés
Auditory temporal resolution in children using cochlear implantation
Palabras clave en inglés
Child
Cochlear implantation
Hearing loss
Hearing tests
Resumen en inglés
Auditory temporal resolution is considered one of the most important skills for acoustic signal processing along the time. It allows the identification of fine differences of speech segmental aspects, such as phonemes and the beginning and end of words in linked phrases. Children using a cochlear implant (CI) present specific characteristics of speech sign decoding and processing, along the time, performed by the CI. Thus, this research aimed at verifying the performance of children fitted with CIs, in temporal resolution tasks. The sample comprised 20 children using CI Nucleus 24/SPRINT (Experimental group - EG) and 20 children with no auditory alterations (Control Group - CG). The Random Gap Detection (RGDT) and Gaps In Noise (GIN) tests were applied to assess the temporal resolution skill through gap detection tests which were applied in free field and 40 dBSL. The statistical tests utilized for data analysis were Student´s t test, for independent data, Mann Whitney´s test and Pearson´s Correlation Coefficient. The children fitted with CIs achieved gap thresholds of 74,13±51 ms on the RGDT and 12,12±2,53 ms on the GIN test, the latter performed by only four out of the 20 children. Gap thresholds for the CG were 18,77±12,29 ms on the RGDT and 6,13±1,27 ms on the GIN test. The difference between the two groups was statistically significant. There was a significant difference in the comparison of the results of tests between the genders of EG, with males outdoing females. No correlation was seen between age and gap detection thresholds for both groups and there was no significance between the time of CI use and the results on the tests for the EG. Even assessing the same hearing skill, no significant correlation was seen between the results of the tests applied. Thus, it was observed that children fitted with cochlear implantation present gap detection thresholds significantly worse than those presented by normally hearing children.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-10-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.