• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2013.tde-23042014-103018
Documento
Autor
Nombre completo
Maíra de Souza Périco
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2013
Director
Tribunal
Krook, Maria Ines Pegoraro (Presidente)
Dutka, Jeniffer de Cassia Rillo
Siécola, Melina Evangelista Whitaker
Título en portugués
Concordância entre os testes perceptivos e a videofluoroscopia no diagnóstico da disfunção velofaríngea
Palabras clave en portugués
Diagnóstico
Fala
Fissura palatina
Fluoroscopia
Insuficiência velofaríngea
Resumen en portugués
Objetivo: Verificar a concordância entre os resultados dos Testes de Emissão de Ar Nasal e de Hipernasalidade e os achados do exame de videofluorocopia no diagnóstico da disfunção velofaríngea, em indivíduos com fissura labiopalatina. Material e Método: A amostra foi constituída por 89 exames de videofluoroscopia e 89 escores dos Testes de Emissão de Ar Nasal e de Hipernasalidade, os quais foram interpretados ou como fechamento velofaríngeo consistente, ou como fechamento velofaríngeo inconsistente, ou como não fechamento velofaríngeo. Foram calculadas a sensibilidade, a especificidade e a concordância entre a interpretação dos achados dos testes perceptivos e os achados davideofluoroscopia. Resultados: Foram encontrados índices de sensibilidade e especificidade de 98% e 37%, respectivamente para o Teste de Emissão de Ar Nasal e de 96% e 63%, respectivamente para o Teste de Hipernasalidade. As porcentagens de concordância entre os escores do Teste de Emissão de Ar Nasal e os exames de videofluoroscopia e os do Teste de Hipernasalidade e os exames de videofluoroscopia para a categoria fechamento velofaríngeo consistente foi de 62% e 70%, respectivamente, para a de fechamento velofaríngeo inconsistente foi de 43% e 47%, respectivamente e para a de não fechamento velofaríngeo foi de 68% e 77%, respectivamente. Conclusão: Houve um bom nível de concordância entre os testes perceptivos e os exames de videofluoroscopia para as categorias fechamento velofaríngeo consistente e não fechamento velofaríngeo, mas não para a de fechamento velofaríngeo inconsistente.
Título en inglés
Agreement between perceptual tests and videofluoroscopy in the diagnosis of velopharyngeal dysfunction
Palabras clave en inglés
Cleft palate
Diagnosis
Fluoroscopy
Speech
Velopharyngeal insufficiency
Resumen en inglés
Objetive: To determine the agreement between the results of the Nasal Air Emission and Hypernasality tests and the videofluoroscopy findings in the diagnosis of velopharyngeal dysfunction in individuals with cleft lip and palate. Material and Methods: The sample consisted of 89 scores of Nasal Air Emission and Hypernasality tests and 89 judgments of videofluoroscopy exam, which were interpreted as consistent velopharyngeal closure, or as inconsistent velopharyngeal closure, or as non velopharyngeal closure. The sensitivity, specificity and agreement between the interpretation of the results of the perceptual tests and the findings of the videofluoroscopy were calculated. Results: The rates found for sensitivity of Nasal Air Emission and Hypernasality tests were 98 and 96%, respectively, and the rates for specificity of Nasal Air Emission and Hypernasality tests were 37% and 63%, respectively. Regarding the percentages of agreement between the Nasal Air Emission test scores and the videofluoroscopy judgments, it was found agreement of 62% for the consistent velopharyngeal closure condition, 43% for the inconsistent velopharyngeal closure and 68% for the non velopharyngeal closure. Between the scores of Hypernasality test and videofluoroscopy judgments the agreement found was 70% for the consistent velopharyngeal closure condition, 47% for the inconsistent velopharyngeal closure and 77% for the non velopharyngeal closure. Conclusion: There was a good level of agreement between the perceptual tests and the videofluoroscopy judgments for the consistent velopharyngeal closure and non velopharyngeal closure conditions, but not for the inconsistent velopharyngeal closure.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-04-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.