• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2007.tde-18102007-163858
Document
Auteur
Nom complet
Ramiro Marcelo Ortíz-Oropeza
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2007
Directeur
Jury
Bramante, Clóvis Monteiro (Président)
Azevedo, Paulo César
Garcia, Roberto Brandão
Titre en portugais
Avaliação microscópica da resposta do tecido subcutâneo de ratos à implantação do Endo-CPM-Sealer e do Clínquer do cimento Portland cinza puro e acrescido com sulfato de cálcio a 2% e 5%
Mots-clés en portugais
Agregado de Trióxido Mineral
Cimento Portland
Endodontia
Resumé en portugais
Ao longo dos últimos anos, têm sido expressivo o interesse pelo estudo do Agregado de Trióxido Mineral (MTA) devido às boas propriedades físico-químicas e biológicas que apresenta. Da mesma forma houve um grande interesse no cimento Portland, já que, segundo os trabalhos científicos encontrados na literatura, apresentam composição e desempenho semelhantes. Este trabalho teve como objetivo avaliar o comportamento biológico do Endo-CPM-Sealer e do clínquer do cimento Portland puro e acrescido com sulfato de cálcio (com 2% e 5% do seu peso total) no tecido subcutâneo de ratos, para analisar as possíveis alterações teciduais que possam induzir. Também foi avaliado o tempo de presa dos quatro cimentos. Empregaram-se 24 ratos machos da linhagem Wistar, divididos em três grupos para cada período experimental (15, 30 e 60 dias). Cada animal recebeu quatro tubos de polietileno (preenchidos com os cimentos experimentais e selados numa das extremidades com guta-percha que serviu como controle) no tecido subcutâneo da região dorsal. Decorridos os períodos experimentais, os animais foram mortos e os tubos foram removidos com tecido adjacente suficiente para análise microscópica. Os resultados mostraram que o Endo-CPM-Sealer, produziu a maior resposta inflamatória nos períodos de 15 e 60 dias, sendo estatisticamente significante somente no primeiro período. O clínquer do cimento Portland puro, foi o que produziu a menor resposta tecidual inflamatória, em todos os períodos. Todos os materiais avaliados apresentaram-se semelhantes no período de 60 dias e não apresentaram diferença estatisticamente significante. Com relação ao tempo de presa inicial, o clínquer do cimento Portland puro, foi o que apresentou o menor valor (5min), e o menor valor do tempo de presa final foi dado pelo Endo-CPM-Sealer (22min), seguido pelo clínquer do cimento Portland puro (55min).
Titre en anglais
Microscopic evaluation of the response of subcutaneous tissue of rats to implantation of Endo-CPM-Sealer and clinker of grey Portland cement, pure or combined with 2% and 5% calcium sulfate
Mots-clés en anglais
Endodontics
Mineral Trioxide Aggregate
Portland cement
Resumé en anglais
During the last years, there has been considerable interest in the investigation of Mineral Trioxide Aggregate (MTA), due to its good physicochemical and biological properties. Similarly, there was great interest in Portland cement, since scientific studies in the literature reveal that these materials present similar composition and performance. This study aimed to evaluate the biological behavior of Endo-CPM-Sealer and clinker of Portland cement, either pure or combined with calcium sulfate (2% and 5% of the total weight), by implantation in subcutaneous tissue of rats, to analyze the possible tissue alterations that may be induced. The setting time of the four cements were also evaluated. The study was conducted on 24 male Wistar rats, divided into 3 groups for each study period (15, 30 and 60 days). Each animal underwent placement of four polyethylene tubes (filled with the experimental materials and sealed with gutta-percha at one end, which served as control) in the subcutaneous tissue at the dorsal region. After the study periods, the animals were killed and the tubes were removed with enough surrounding tissue for microscopic analysis. The results demonstrated that Endo-CPMSealer caused greatest inflammatory response at 15 and 60 days, with a statistically significant difference only on the first period. Pure clinker of Portland cement produced the least inflammatory response at all periods. All materials were similar at 60 days, without statistically significant difference. Concerning the initial setting time, pure clinker of Portland cement exhibited the shortest time (5min); the shortest final setting time was observed for Endo-CPM-Sealer (22min), followed by pure clinker of Portland cement (55min).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-10-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.