Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2011.tde-24082011-093513
Document
Author
Full name
Max Laurent Albarracín
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2011
Supervisor
Committee
Rubo, Jose Henrique (President)
Oliveira, Pedro Cesar Garcia de
Silva, Renato Oliveira Ferreira da
Title in Portuguese
Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas
Keywords in Portuguese
Biomecânica
Coroa unitária implantossuportada
Extensômetro
Implante dentário
Abstract in Portuguese
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável).
Title in English
Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns
Keywords in English
Biomechanics
Dental implant
Single unit implant-supported crown
Strain gage
Abstract in English
The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-08-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.