• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2007.tde-15102007-095104
Document
Author
Full name
Flora Freitas Fernandes Távora
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2007
Supervisor
Committee
Porto, Vinícius Carvalho (President)
Machado, Ana Lucia
Oliveira, Pedro César Garcia de
Title in Portuguese
Efeito de sucessivos ciclos de desinfecção por microondas sobre a microdureza e rugosidade superficial de diferentes bases de próteses totais: estudo longitudinal
Keywords in Portuguese
Desinfecção
Resinas acrílicas
Abstract in Portuguese
O objetivo desse estudo foi investigar longitudinalmente, o efeito de sucessivos ciclos de desinfecção sobre as propriedades de microdureza e rugosidade superficial de 4 diferentes resinas acrílicas. Foram confeccionados 200 corpos de prova, utilizando um material para base de dentaduras (Lucitone 550) e três materiais rígidos para reembasamento (Jet, Kooliner e Tokuyama Rebase II Fast), os quais foram divididos, para cada resina, em cinco grupos: imersos em água (controle) e submetidos à irradiação por microondas em quatro combinações diferentes de potência-tempo. Esses grupos foram avaliados em relação à rugosidade superficial (Ra-µm) e microdureza Knoop (KHN) em um período anterior às desinfecções e após 30, 90 e 180 ciclos de desinfecção. Os dados foram submetidos à análise de variância, seguida por teste de Tukey a 5%. As principais alterações nos valores de microdureza (diminuição) e rugosidade superficial (aumento) ocorreram após 30 ciclos de desinfecção em microondas. Após esse período existiu uma tendência para a estabilização dos valores dessas propriedades, mesmo quando ciclos adicionais (90 e 180 ciclos) foram realizados. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) não foram os principais fatores que tiveram influência sobre a propriedade de microdureza. É provável que a redução dos valores de microdureza tenha sido mais dependente da sorpção de água do que da energia de microondas por si só. O principal efeito sobre a microdureza através da irradiação por microondas parece ser o efeito da água. A exposição da prótese a fluidos como água e saliva é uma condição que não pode ser evitada. Esse comportamento não foi observado para a rugosidade superficial. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) tiveram influência sobre a propriedade de rugosidade superficial. De maneira geral observou-se que os valores de rugosidade superficial dos espécimes somente imersos em água foram menores do que os valores dos espécimes irradiados. Apesar da rugosidade de alguns espécimes ter ficado acima de 0.2 um, isso não parece contra-indicar a desinfecção por microondas. As técnicas convencionais de acabamento e polimento aplicadas para as outras superfícies dificilmente atingem níveis de rugosidade superficial inferiores a 0,2 µm. Dessa maneira parece ser prudente a afirmação de que a desinfecção através da energia de microondas pode ser utilizada para a desinfecção de próteses.
Title in English
Effect of successive microwave disinfection cycles on the hardness and roughness of different denture base resins: a longitudinal study
Keywords in English
Acrylic resins
Disinfection
Abstract in English
The objective of this study was to investigate the longitudinal effect of microwave disinfection on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 200 specimens were fabricated using one denture base material (Lucitone 550; n=50) and three hard chairside reliners (Jet; n=50, Kooliner; n=50, Tokuyama Rebase II Fast; n=50), which were immersed in water (control), and submitted to microwave disinfection at four different arrangements of power and time. These specimens were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before disinfection, after 30, 90 and 180 disinfection cycles). Data were analyzed by Variance Analysis which was followed by the Turkey's test at a level of 5%. The principal alterations on hardness (reduction) and on roughness (elevation) occurred after 30 disinfection cycles. Both of the properties remained stable after this period, even after 90 and 180 disinfection cycles. The different arrangements of power and time carried out for the experimental groups did not have influence on hardness. It is possible that this property was more affected from water sorption than microwave energy only. During its clinical use, the denture is exposed to water and saliva and it seems that this condition cannot be prevented. This fact was not observed for roughness. The different arrangements of power and time carried out for the experimental groups had influence on roughness. It was observed that the control group had lower roughness values when compared to the experimental groups. The roughness values of some specimens were greater than 0.2 um. However, this fact does not compromise the indication of microwave disinfection. The finishing and polishing techniques commonly used for the other surfaces of the denture do not get roughness values below 0.2 um. Therefore, it is very likely that microwave disinfection could be recommended for the disinfection of dentures.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-10-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.