• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.25.2010.tde-02062011-144503
Document
Author
Full name
Rafael Tobias Moretti Neto
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2010
Supervisor
Committee
Rubo, Jose Henrique (President)
Araujo, Carlos dos Reis Pereira de
Dekon, Stefan Fiuza de Carvalho
Ferreira, Paulo Martins
Sousa, Edson Antonio Capello
Title in Portuguese
Avaliação da deformação do intermediário e região perimplantar de próteses implanto-suportada unitárias parafusada: estudo através da extensometria
Keywords in Portuguese
Assentamento passivo
Extensômetros
Osso trabecular
Poliuretano
Abstract in Portuguese
O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram diferenças antes e após a aplicação da cerâmica.
Title in English
Evaluation of abutment and perimplantar region deformation of implant-supported screwed prostheses: an study using strain gauges
Keywords in English
Passive fit
Polyurethane
Strain gauge
Trabecular bone
Abstract in English
The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-06-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.