• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.25.2000.tde-05042005-102734
Document
Auteur
Nom complet
Maria Helena Ferreira Vasconcelos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2000
Directeur
Jury
Janson, Guilherme dos Reis Pereira (Président)
Cuoghi, Osmar Aparecido
Gandini Júnior, Luiz Gonzaga
Henriques, Jose Fernando Castanha
Tavano, Orivaldo
Titre en portugais
Avaliação de um programa de traçado cefalométrico
Mots-clés en portugais
cefalometria em odontologia
programa de traçado
programa dentofacial planner
Resumé en portugais
Esta pesquisa objetivou avaliar comparativamente o programa de traçado cefalométrico computadorizado Radiocef 2.O, quanto à confiabilidade e precisão, em relação ao método de traçado manual e ao programa Dentofacial Planner 7.02. A amostra constou de 50 radiografias cefalométricas laterais de boa qualidade, recentemente obtidas, pertencentes à clínica de pós-graduação da disciplina de Ortodontia da Faculdade de Odontologia de Bauru, da Universidade de São Paulo, de pacientes de ambos os sexos, na faixa etária compreendida entre 11 e 24 anos de idade, constituindo exemplares de diferentes tipos de má oclusão. As radiografias compuseram 4 grupos experimentais, de acordo com a forma de medição executada: Grupo 1) método manual; Grupo 2) a partir da digitalização dos traçados no programa Radiocef 2.0; Grupo 3) a partir da digitalização das radiografias no programa Radiocef 2.0; e Grupo 4) a partir da digitalização dos pontos cefalométricos no programa Dentofacial Planner 7.02. Para compor as medições, foram selecionadas medidas angulares e lineares. Os testes estatísticos empregados foram a análise de variância (ANOVA) e o teste de Kruskal-Wallis, para a comparação inter-grupos. Os resultados inter-grupos mostraram-se comparáveis, sem diferenças estatisticamente significantes, ao nível de 5%. Tais resultados levaram às seguintes conclusões: 1a) o programa de traçado cefalométrico computadorizado Radiocef 2.O pode ser confiavelmente utilizado como recurso auxiliar no diagnóstico, plano de tratamento, acompanhamento e avaliação de tratamentos ortodônticos, nos âmbitos clínico e/ou de pesquisa; 2a) este programa também pode ser confiavelmente utilizado para efetuar medições a partir da digitalização dos traçados, além da forma proposta pelo fabricante.
Resumé en anglais
The objective of this study was to comparatively evaluate the cephalometric software namely Radiocef 2.0, regarding reliability and precision, as compared to the conventional manual tracing and measuring procedures, and to the software Dentofacial Planner 7.02. The sample consisted of 50 good quality lateral head films from patients of both gender at the 11 to 24-year age range belonging to the files of the orthodontic graduate clinic at Bauru Dental School, University of São Paulo. The radiographs were traced and measured by different methodologies generating four groups as follows: Group 1) the radiographs were manually traced and measured; Group 2) the cephalograms and landmarks were scanned and measured with Radiocef 2.0 software; Group 3) the radiographs were scanned and measured with Radiocef 2.0 software; and Group 4) the landmarks were digitized and measured with Dentofacial Planner 7.02 software. Linear and angular measurements were performed and an analysis of variance and a Kruskal-Wallis test were conducted for intergroup comparison. Results demonstrated no statistically significant differences between the groups. Therefore, it was concluded that the software is reliable to be used for clinical and investigative purposes and that Radiocef 2.0 can be used by either scanning the cephalograms and landmarks or by scanning the radiograph itself.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
MariaHelena.pdf (583.79 Kbytes)
Date de Publication
2005-04-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.