• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2010.tde-18082010-100049
Document
Auteur
Nom complet
Ricardo Virgolino Carvalho da Silva
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2010
Directeur
Jury
Franco, Eduardo Batista (Président)
Coutinho, Margareth da Silva
Wang, Linda
Titre en portugais
Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica
Mots-clés en portugais
Preparo da cavidade dentária
Técnicas de instrumentação
Resumé en portugais
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários
Titre en anglais
Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation
Mots-clés en anglais
Cavity preparation
Instrumentation techniques
Resumé en anglais
The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2010-08-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.