Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.1996.tde-06042005-094511
Documento
Autor
Nombre completo
Renata Bastos Del'Hoyo Fernandes
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 1995
Director
Tribunal
Navarro, Maria Fidela de Lima (Presidente)
Carvalho, Ricardo Marins de
Taga, Eulazio Mikio
Título en portugués
Avaliação in vitro da liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes.
Palabras clave en portugués
dentística
materiais dentários
Resumen en portugués
O objetivo deste estudo in vitro foi avaliar e comparar o padrão e a quantidade de liberação de flúor de cimentos de ionômero de vidro forradores e cimentantes após períodos de 24 horas, 7 dias e 28 dias em água desionizada. Foram confeccionados 6 corpos de prova em forma de disco para cada material e cada período de leitura que, após a reação de endurecimento inicial, foram suspensos em recipientes plásticos contendo 18 mL de água desionizada. No momento da leitura, realizada a cada 6 horas no período de 24 horas, a cada 24 horas no período de 7 dias e a cada 7 dias no período de 28 dias, adicionou-se ao meio de armazenagem 2 mL de solução tampão TISAB III. A concentração de íons flúor em solução foi avaliada mediante leitura potenciométrica utilizando-se um aparelho analisador de íons. Vidrion C e XR Ionomer apresentaram as maiores quantidades de liberação de flúor. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I e Shofu I ocuparam uma posição intermediária e o Zionomer pó/líquido liberou a menor quantidade de flúor. Contudo, o padrão de liberação de flúor foi semelhante para todos os materiais testados.
Resumen en inglés
The objective of the present in vitro study was to evaluate and compare the pattern and the quantity of fluoride release of lining and luting glass ionomer cements after 24 hours, 7 days and 28 days in de-ionized water. Six disc-shaped specimes were made for each material and for each reading period. After the initial hardening reaction, they were pierced and suspended in plastic containers with 18 mL of de-ionized water. Readings were carried out every six hours in the 24-hour period, every 24 hours in the 7- day period, and every 7 days in the 28-day period, when 2 mL of TISAB III buffer solution was added. The concentration of fluoride ions in solution was evaluated through potenciometric readings using an ion analyser device. Vidrion C and XR Ionomer showed the highest quantity of fluoride release. Ketac-Bond, Vitrebond, Ketac-Cem, GC Fuji I and Shofu I were intermediary in rank, whereas powder/liquid Zionomer released the least quantity of fluoride. However, the pattern of fluoride release was the same to all the tested materials.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Renata.pdf (942.00 Kbytes)
Fecha de Publicación
2005-04-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.