• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.25.1999.tde-05012005-102357
Document
Auteur
Nom complet
Marco Polo Marchese
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 1999
Directeur
Jury
Freitas, Cesar Antunes de (Président)
Araujo, Carlos dos Reis Pereira de
Bombonati, Paulo Edson
Bonachela, Wellington Cardoso
Mollo Junior, Francisco de Assis
Titre en portugais
Fidelidade de Troquéis de Gesso, Obtidos a Partir de Moldes de Vários Elastômeros, Através de Duas Diferentes Técnicas de Moldagem.
Mots-clés en portugais
elastomeros
moldagem odontológica
moldes dentários
troqueis de gesso
Resumé en portugais
As restaurações fixas são rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisão na adaptação destas é influênciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastomêro eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado um coroa-padrão que se adapta com precisão a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequações suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JÖRGENSEN6 e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padrão foi posicionada nos troquéis e avaliada, quanto à sua precisão de adaptação, em um microscópio de medição de profundidade. Os resultados estatístico mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhantes entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado.
Resumé en anglais
Fixed restorations are usually produced on gypsum dies obtained from a prepared tooth mold and its precise adaptation is directly influenced by the properties of the impression materials. The objective of this study was to compare the performance of five impression materials and different methods of impression. Materials were tested using the putty-wash method being the first impression realeased in 1 or 2 mm (for Express and President) and the individual resin tray shell (Express, Impregum F, Imprint, Permlastic e Predident). The deviced used by ARAÚJO; JÖRGENSEN6 and the Vel-Mix (type IV) gypsum were used. The adaptation of one standard-crown to the dies was analysed with a depth measuring microscope. The results showed that Impregum F and Imprint (with a shell) gave the best results, followed by Express and President (putty/wash – 2 mm) and Express (putty/wash – 1 mm). The results with Permlastic and Express (shell) were less satisfactory and the difference between them wasn’t statistically significant. Express (shell) was not statistically different from the President (shell), and the worse result was given by the President (putty/wash - 1 mm) when compared to all the others.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
MarcoMarchese.pdf (682.07 Kbytes)
Date de Publication
2005-01-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.