• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2017.tde-27112017-151455
Documento
Autor
Nombre completo
Leonardo Medina Poveda
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Santos, Marcelo dos (Presidente)
Brzozowski, Margarete Elisabete
Medeiros, João Marcelo Ferreira de
Prokopowitsch, Igor
Título en portugués
Avaliação da resistência à fadiga cíclica flexural dos instrumentos Reciproc Blue e WaveOne Gold
Palabras clave en portugués
Curvatura
Fadiga cíclica
Fratura
Níquel-Titânio
Resumen en portugués
Inquestionavelmente, inovações ocorridas nos últimos anos no preparo do canal radicular revolucionaram o tratamento endodôntico. Dentre elas, destaca-se o tratamento térmico recristalizador da liga de níquel-titânio na confecção de limas endodônticas, o qual aumentou de sobremaneira sua flexibilidade e as capacidades de flexibilidade, torção e resistência à fadiga cíclica flexural quando comparadas às limas de níquel-titânio convencionais fabricadas até então. O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel-titânio tratados termicamente Reciproc Blue R25 (VDW) e WaveOne Gold Primary (Dentsply-Maillefer) em um dispositivo desenvolvido especificamente para realizar ensaios flexurais dinâmicos. As limas selecionadas possuíam conicidade 0,08 mm e 0,07 mm respectivamente, com diâmetros de ponta 0,25 mm e foram utilizadas no motor elétrico VDW Silver Reciproc (VDW) em movimento reciprocante específico de cada sistema. Os instrumentos foram divididos em 2 grupos de 15 limas e testados em canais de aço simulados com o ângulo de 60º e raio de curvatura de 5mm. O número de ciclos e o tempo em segundos até a ocorrência de fratura dos instrumentos foram registrados e estatisticamente avaliados. As limas Reciproc Blue R25 apresentaram desempenho significativamente melhor (P<0,05), por meio do maior número de ciclos e de tempo até a fratura quando comparadas com as limas WaveOne Gold. Assim, conclui-se que o sistema Reciproc Blue R25 foi mais seguro quanto à resistência à fadiga flexural no ensaio realizado quando comparado ao sistema WaveOne Gold Primary em movimento reciprocante.
Título en inglés
Evaluation of cyclic flexural fatigue of Reciproc Blue and WaveOne Gold instruments
Palabras clave en inglés
Curvature
Cyclic fatigue
Fracture
Nickel-Titanium
Resumen en inglés
Innovations that have occurred in recent years in the preparation of the root canal have revolutionized endodontic treatment. Among them, the heat treatment of the nickel-titanium alloy in the manufacture of endodontic files, which greatly increased the flexibility, torsional and flexural fatigue resistance capacities when compared to the conventional nickel-titanium files manufactured until then. The present study aimed to evaluate the resistance to flexural cyclic fatigue of thermally treated Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply-Maillefer) instruments in a device specifically developed to perform dynamic flexural tests. The selected files had taper 0.08 mm and 0.07 mm respectively, with tip diameters of 0.25 mm and were used in the reciprocating movement of each system in the VDW Silver Reciproc (VDW) electric motor. The instruments were divided into 2 groups of 15 files and tested in simulated steel channels with angle of 60º and radius of curvature of 5mm. The number of cycles and the time in seconds until the occurrence of fracture of the instruments were recorded and statistically evaluated. The Reciproc Blue R25 files presented significantly better performance (p <0.05), by the higher number of cycles and time to fracture when compared to WaveOne Gold files. Thus, it was concluded that the Reciproc Blue R25 system was safer than the WaveOne Gold Primary reciprocating system in terms of resistence of flexural fatigue
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-12-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.