• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2017.tde-06032017-123428
Documento
Autor
Nombre completo
Roberta Bezerra Pontes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Mattos, Beatriz Silva Camara (Presidente)
Nogueira, Fernando Neves
Sousa, Andréa Alves de
Witzel, Andréa Lusvarghi
Título en portugués
Análise por meio de elementos finitos das tensões ósseas geradas por prótese obturadora maxilar implanto-retida através dos sistemas de retenção O'ring e magneto
Palabras clave en portugués
Análise de elementos finitos
Implante
Magneto
O'ring
Prótese obturadora
Resumen en portugués
A Análise de Elementos Finitos (AEF) vem sendo utilizada em diversos trabalhos na Odontologia, pois possibilita que o estudo in vitro simule uma situação clínica real. Neste estudo utilizou-se a Análise de Elementos Finitos para avaliar as tensões geradas por prótese total obturadora maxilar Classe II de Okay retida por implantes e utilizando os sistemas de retenção O'ring e magneto. Avaliaram-se as tensões geradas no tecido ósseo, gengivo-mucoso e barras metálicas após a aplicação de cargas nas mesas oclusal e incisal. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo edentado adulto, onde se simulou uma perda óssea condizente com uma maxilectomia, simulando a Classe II de Okay. Foram posicionados quatro implantes na maxila, na região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, todos unidos por barra metálica onde se instalaram os sistemas de retenção escolhidos para esse estudo. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo BioCAD 3D, onde foram incorporados os modelos CAD dos implantes, UCLAS e dos sistemas de retenção, obtendo-se dois modelos, Modelo 1, O'ring e Modelo 2, magneto. A malha de elementos finitos foi gerada pelo programa Ansys® e nela foi aplicada uma força de 80 N na plataforma oclusal e 35 N na plataforma incisal, simultaneamente. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal e os valores quantitativos expressos em MPa. O deslocamento da prótese obturadora, no sentido da região sem suporte ósseo, foi maior no Modelo 1, O'ring. A mucosa de revestimento, o osso cortical e o osso medular sofreram tensões de tração e compressão que variaram de acordo com o sistema de retenção utilizado, sendo que o Modelo 2, magnetos, transferiu mais tensões para essas estruturas. O Modelo 2, magnetos, apresentou tensões na região cervical de três implantes, enquanto o Modelo 1, O'ring, apresentou somente em um implante. A barra metálica com retenções do tipo magneto sofreu tensões equivalentes de von Mises com valores semelhantes a barra metálica com O'ring, no entanto a área envolvida foi maior em abrangência. Baseando-se nos resultados apresentados neste estudo, a utilização de ambos sistemas de retenção é indicada para reabilitação com próteses obturadoras implantorretidas, no entanto o modelo que utilizou retenção com O'ring, apresentou comportamento biomecânico mais favorável para esse tipo de reabilitação.
Título en inglés
Finite elements analysis of bone stress generated by an implant retained maxillary obturator prosthesis with Ball/O'ring and magnetic attachment
Palabras clave en inglés
Ball/O'ring
Finite elements analysis
Implant
Magnetic attachment
Obturator prosthesis
Resumen en inglés
The Finite Elements Analysis (FEA) has been used in several studies in Dentistry, as it allows that an in vitro study simulates a clinical scenario. In this study the Finite Element Analysis was used to evaluate the bone stress generated by an Okay Class II obturator implant retained prosthesis having Ball/O'ring and magnetic attachment. The tensions generated over bone, soft tissue and metallic bars were evaluated after applied loads which simulated the masticatory activity. The Finite Elements Analysis, were done utilizing a digital model developed from a computer tomography of an adult subject, where it was simulated a bone loss in accordance with a maxillectomy, simulating an Okay Class II. Four implants were set in the left maxilla, on the lateral incisor, canine, second premolar and first molar, all linked by a metallic bar where the retention system chosen for this study was installed. The Rhinoceros® program, version 5.0 was used to generate the BioCAD 3D model, where the implant CAD models, UCLAS and retention systems were incorporated, obtaining two models, Model 1, Ball/O'ring and Model 2, magnetic attachment. The finite elements mesh was generated by Ansys® program and an 80 N force was applied over it on the occlusal platform and 35 N on the incisal platform. A qualitative analysis was performed, corresponding to the maximum main stress and the quantitative values expressed on MPa. The obturator prosthesis movement in the direction of the area without the bone support was greater on the Model 1, O´Ring. The soft tissue, the cortical and medullar bones suffered compression and tensions which variated according with the retention system used, the Model 2, magnetic attachment, was the one transferring more stress to these structures. The Model 2, magnetic attachment, presented tensions on the cervical region at 03 implants, while the Model 1, Ball/O'ring, presented only at one implant. The metallic bar with magnetic attachment suffered von Mises equivalent tensions with similar values to the metallic bar with Ball/O'ring, however it covered a greater area. Based on the results obtained in this study, the use of both retention systems is indicated in the rehabilitation with implant retained obturator prosthesis, though the Model 1, Ball/O'ring, presented a biomechanical behavior more suitable to this type of rehabilitation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-03-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.