Doctoral Thesis
DOI
https://doi.org/10.11606/T.23.2008.tde-21012009-144722
Document
Author
Full name
Vilmar Antonio Ferrazzo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2008
Supervisor
Committee
Morea, Gladys Cristina Dominguez (President)
Aidar, Luis Antonio de Arruda
Chilvarquer, Israel
Grehs, Renésio Armindo
Tortamano, André
Title in Portuguese
Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle
Keywords in Portuguese
Ancoragem absoluta
Cão Beagle
Ensaio de tração
Mini-parafusos
Ortodontia
Abstract in Portuguese
Com o objetivo de avaliar a influência do processo de cicatrização óssea sobre o desempenho biomecânico de mini-parafusos utilizados como ancoragem em ortodontia, foram inseridos 60 mini-parafusos (1,6 x 6mm) auto-rosqueantes (Tomas® Dentaurum / Germany) na maxila e na mandíbula de 5 cães adultos da Raça Beagle. Os pré-molares (P1, P2, P3, P4) superiores e inferiores foram extraídos três meses antes da inserção vertical dos mini-parafusos. Os cães foram sacrificados nos dias 0, 2, 7, 15 e 30 após a instalação dos mini-parafusos. Os maxilares foram dissecados e os corpos de provas contendo os mini-parafusos foram preparados para avaliação da resistência à tração na Máquina de Ensaios Universal EMIC® 2000, utilizando uma garra desenvolvida especificamente para este estudo. Os valores e gráficos correspondentes ao desempenho mecânico foram imediatamente gerados e registrados pelo programa de aquisição Tesc 3.01®. As possíveis diferenças entre os períodos de cicatrização foram avaliadas pela análise de variância (ANOVA) e pelo teste de comparações múltiplas de Bonferroni. Os resultados demonstraram um índice de sucesso de 100% dos mini-parafusos inseridos. Após a dissecação dos segmentos ósseos, verificou-se que em alguns casos a superfície da rosca ficou parcialmente exposta, razão pela qual o cálculo da resistência à tração (média na maxila de: 141,76 ± 92,82 Ncm a 237,02 ± 78,34 Ncm e média na mandíbula de: 156,86 ± 75,55 Ncm a 328,76 ± 82,17 Ncm) foi feito em relação à área real de inserção (maxila: 24,01 ± 6,09mm2 e mandíbula: 22,88 ± 5,31mm2), observando-se um valor médio por mm2 significativamente maior na mandíbula (11,60 ± 5,22 Ncm) quando comparado à maxila (8,22 ± 5,04 Ncm). A relação entre a intensidade da força de tração (Ncm), superfície inserida (mm2) e períodos de cicatrização não apresentaram diferenças significantes (p= 0,126). Com base nestes resultados podemos concluir que os mini-parafusos avaliados demonstraram excelente desempenho biomecânico nos diferentes períodos de cicatrização analisados, apresentando maior resistência à tração no osso mandibular.
Title in English
Pull-out strength of unloaded orthodontic mini-screws at different healing periods. In vivo study in Beagle dogs
Keywords in English
Absolute anchorage
Beagle dogs
Mini-screw
Orthodontics
Pull-out strength
Abstract in English
With the purpose of evaluating the influence of bone healing process on the biomechanical performance of mini-screws used as anchorage in orthodontics, 60 self-tapping (Tomas® - Dentaurum / Germany) mini-screws were inserted (1.6 x 6 mm) in the maxilla and in the mandible of 5 adult Beagle dogs. Upper and lower premolars (P1, P2, P3, P4) were extracted three months before the vertical insertion of mini-screws. The dogs were sacrified on days 0, 2, 7, 15 and 30 after the insertion of mini-screws. The jaws were dissected and the bone blocks, containing the miniscrews, were prepared to the axial pull-out strength in the Universal Testing Machine EMIC ® 2000, using a device developed specifically for this study. The values and graphics for the mechanical performance were immediately generated and recorded by the acquisition program. The clinical success rate of mini-screws was 100%. The possible differences between the healing periods were analyzed by Bonferroni´s multiple test comparisons and variance analysis (ANOVA). After the dissection of the bone segments, it was found that in some cases, the mini-screw thread was not fully inserted into the bone, reason why the pull-out strength (average of the maxilla: 141.76 ± 92.82 Ncm to 237.02 ± 78.34 Ncm and average in the mandible of 156.86 ± 75.55 Ncm to 328.76 ± 82.17 Ncm) was evaluated in relation to the real area of insertion (maxilla: 24.01 ± 6.09 mm2 and mandible: 22.88 ± 5.31 mm2). Mean value/mm2 were significantly higher in the mandible (11.60 ± 5.22 Ncm/mm2) than the maxilla (8.22 ± 5.04 Ncm/mm2). There was no statistically significant difference (p = 0126) between pull-out strength (Ncm), surface inserted (mm2) and the observed healing periods. Based on these results it can be concluded that mini-screws evaluated in this study demonstrated an excellent biomechanical behavior in all different periods of healing, showing more resistance to traction in the mandibular bone.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2009-03-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI