• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2008.tde-20012009-105516
Document
Auteur
Nom complet
Cristiane Aparecida de Assis Claro
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Abrao, Jorge (Président)
Fantini, Solange Mongelli de
Kanashiro, Lylian Kazumi
Lagana, Dalva Cruz
Pinto, Ary dos Santos
Titre en portugais
Análise da distribuição de tensões, em modelo fotoelástico, decorrente de diferentes arcos de intrusão de incisivos inferiores
Mots-clés en portugais
Biomecânica
Distribuição de forças
Fios ortodônticos
Fotoelasticidade
Intrusão
Ligas metálicas
Ortodontia
Reabsorção radicular Movimento ortodôntico
Resumé en portugais
No presente estudo foi analisada a distribuição de tensões, na região anterior de modelo fotoelástico, gerada por arcos de intrusão de incisivos inferiores. Compararam-se as tensões entre diferentes arcos. E ainda, em cada tipo de arco, compararam-se as tensões entre terços radiculares e entre incisivos. O modelo fotoelástico foi construído simulando a extrusão dos incisivos. Foram confeccionados sessenta arcos de intrusão, sendo quinze de cada tipo de mecânica: arco contínuo de Burstone, arco utilitário de Ricketts, arco com dobra de ancoragem usado na mecânica de Begg e arco com curva de Spee reversa usado na mecânica de Tweed. A força de ativação foi mensurada em 50gf na região da linha média. O modelo fotoelástico foi observado em polariscópio circular, na configuração de campo escuro, e fotografado. As fotografias frontais foram analisadas, e as ordens de franjas em cada região registradas. A repetibilidade do método foi identificada pela análise de kappa. A comparação entre as tensões foi realizada pelo teste de Kruskall-Wallis complementado com teste de Dunn. Os resultados obtidos permitiram concluir que na região apical, as maiores magnitudes de tensões foram geradas pelo arco utilitário de Ricketts, seguido pelo arco contínuo de Burstone. Na região média, as maiores magnitudes de tensões foram geradas pelo arco utilitário de Ricketts, seguida por arco contínuo de Burstone, arco com dobra de ancoragem e arco com curva de Spee reversa. Na região cervical, as maiores magnitudes de tensões foram decorrentes do arco utilitário de Ricketts, seguido por arco com curva de Spee reversa e arco com dobra de ancoragem. Os arcos contínuos de Burstone apresentaram as menores tensões na região cervical. Ao se comparar as ordens de franjas entre os terços radiculares, de cada dente, em todos os arcos analisados, as maiores magnitudes de tensões foram observadas nas regiões cervicais. Ao se comparar as ordens de franjas entre os dentes, em cada terço radicular, no arco contínuo de Burstone, as maiores magnitudes de tensões foram observadas nos incisivos laterais. Entretanto, no arco utilitário de Ricketts e no arco com dobra de ancoragem, as maiores magnitudes de tensões foram observadas nos incisivos centrais. No arco com curva de Spee reversa, as maiores magnitudes de tensões foram identificadas nos incisivos esquerdos. Portanto, os resultados do presente estudo permitiram a visualização e compreensão dos efeitos dos diversos arcos de intrusão. Entretanto, estes resultados devem ser observados com cautela, requerendo mais pesquisas que confirmem a reprodutibilidade do método e dos resultados.
Titre en anglais
Stress distribution analysis caused by different intrusion arches on lower incisors in photoelastic model
Mots-clés en anglais
Biomechanics
Distribution of forces
Intrusion
Metallic alloys
Orhodontic wires
Orthodontic movement
Orthodontics
Photoelasticity
Root reabsorption
Resumé en anglais
In the present study, the distribution of stresses caused by intrusion arches on lower incisors, in the anterior region of photoelastic model, was analyzed. The stresses were compared among the different arches. Additionally, stresses were also compared among the root thirds, as well as among the incisors for each arch type. The photoelastic model was constructed simulating the extrusion of incisors. Sixty intrusion arches were made up, corresponding to fifteen of each type: Burstone continuous arches, Ricketts utility arches, anchorage bend arches used in Begg mechanics and reverse Spee curved arches used in Tweed mechanics. Activation force was measured at 50gf in the midline. The photoelastic model was observed under circular polariscope, in dark-field configuration, and photographed. Frontal photographs were analyzed, and fringe order in each region was recorded. Method repeatability was identified by kappa analysis. A comparison among stresses was carried out using Kruskall-Wallis test and complemented by the Dunn test. Results obtained led to the conclusion that in the apical region, the major stress magnitudes were generated by the Ricketts utility arch, followed by the Burstone continuous arch. In mid-region, the major stress magnitudes were generated by Ricketts utility arch, followed by the Burstone continuous arch, anchorage bend arch, and arch wire with a reverse curve of Spee. In the cervical region, the major stress magnitudes stemmed from Ricketts utility arch, followed by arch with reverse curve of Spee and the anchorage bend arch. The Burstone continuous arches presented the least stresses in the cervical region. On comparing fringe orders among root thirds, of each tooth, in all arches analyzed, major magnitudes of stresses were observed in the cervical regions. On comparing fringe orders among teeth, in each root third, the major magnitudes of stresses were observed in lateral incisors in Burstone continuous arches. However, in both Ricketts utility arches and anchorage bend arches the major stresses magnitudes were observed in central incisors. In arch with a reverse curve of Spee the major magnitudes of stresses were identified in left incisors. Consequently the results in the present study allowed a visualization and understanding of the effects of the diverse intrusion arches. However, such results should be observed with caution, requiring further study to confirm method reproducibility as well as results.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-03-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.