Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2015.tde-17062015-130723
Document
Auteur
Nom complet
Sergio Rodrigues Sizo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Mori, Matsuyoshi (Président)
Abla, Marcelo Sabbag
Lagana, Dalva Cruz
Rocha, Max Pinto da Costa da
Santos, Sidney Saint Clair
Titre en portugais
Distribuição das tensões promovidas por implantes cone Morse inseridos em diferentes níveis ósseos: análise fotoelástica e método dos elementos finitos
Mots-clés en portugais
Análise fotoelástica
Cargas compressivas
Implante dentário
Método dos elementos finitos
Resumé en portugais
Ainda não existe um consenso sobre o nível em que os implantes cone Morse devem ser inseridos em relação à crista ósse alveolar. A literatura mostra diversas pesquisas em animais e laboratoriais com implantes posicionados acima, abaixo ou ao nível da crista. Contudo, diferentes metodologias e técnicas dificultam a definição do melhor nível de localização. O presente trabalho optou por analisar qualitativa e quantitativamente por meio da fotoelasticidade e do método dos elementos finitos (MEF), implantes em diferentes níveis de inserção sob carga compressiva estática, visando elucidar esse tema. Quatro níveis foram simulados: 1 mm acima da crista (AC); ao nível da crista (AN); 1 mm abaixo da crista sem aposição óssea sobre a plataforma (AB-S); e 1 mm abaixo da crista com aposição óssea sobre a plataforma (AB-C). Os resultados fotoelásticos demonstraram maiores valores de ordem de franja na região apical e menores na região cervical, em todos os modelos, independente do tipo de carga. No MEF verificou-se que o aprofundamento do implante da posição AC para AB-S reduziu progressivamente as tensões de von Mises na região cortical independente do tipo de carga, respectivamente, 0,5595 - 0,3842 Mpa nas cargas cêntricas e 1,5261 - 0,9787 MPa nas excêntricas. Concluiuse que houve redução na concentração de tensões posicionado-se o implante abaixo do crista óssea e uma tendência de aumento de tensão nas amostras AB-C, provavelmente devido à tração do osso existente sobre a plataforma do implante.
Titre en anglais
Stress distribution promoted by Morse taper connection implants inserted in different bone levels: photoelastic analysis and finite element method
Mots-clés en anglais
Compressive loads
Dental implant
Finite element analysis
Photoelastic analysis
Resumé en anglais
There is still no consensus on the level that the Morse taper implants should be inserted in relation to the alveolar crestal bone. The literature shows several studies in animals and laboratory implant positioned above, at level or subcrestal. However, different methodologies and techniques make it difficult to define the best level of the implant. This study analyzes qualitatively and quantitatively by using photoelastic analysis and the finite element method (FEM), implants at different levels under static compressive load, to elucidate this issue. Four levels were simulated: 1 mm above the crest (AC); the crest level (AN); 1 mm below the crest free bone apposition on the platform (AB-S); and 1 mm below the crest with bone apposition on the platform (ABC). Photoelastic results demonstrated higher fringe order of values in the apical region and lower in the cervical region, in all models, regardless of the loading type. In MEF found that the deepening of the implant position from AC to AB-S progressively reduced von Mises equivalent stresses in cortical region independent of the load type, respectively, 0.5595 - 0.3842 MPa in centric loads and 1.5261 - 0.9787 MPa in eccentric loads. It was concluded that there was a reduction in stress concentration on the implant positioned below the alveolar crest and a tendency of an increase in tension in the AB-C samples, probably due to traction on the existing bone implant platform.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-06-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.