• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2015.tde-17062015-130723
Documento
Autor
Nombre completo
Sergio Rodrigues Sizo
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Mori, Matsuyoshi (Presidente)
Abla, Marcelo Sabbag
Lagana, Dalva Cruz
Rocha, Max Pinto da Costa da
Santos, Sidney Saint Clair
Título en portugués
Distribuição das tensões promovidas por implantes cone Morse inseridos em diferentes níveis ósseos: análise fotoelástica e método dos elementos finitos
Palabras clave en portugués
Análise fotoelástica
Cargas compressivas
Implante dentário
Método dos elementos finitos
Resumen en portugués
Ainda não existe um consenso sobre o nível em que os implantes cone Morse devem ser inseridos em relação à crista ósse alveolar. A literatura mostra diversas pesquisas em animais e laboratoriais com implantes posicionados acima, abaixo ou ao nível da crista. Contudo, diferentes metodologias e técnicas dificultam a definição do melhor nível de localização. O presente trabalho optou por analisar qualitativa e quantitativamente por meio da fotoelasticidade e do método dos elementos finitos (MEF), implantes em diferentes níveis de inserção sob carga compressiva estática, visando elucidar esse tema. Quatro níveis foram simulados: 1 mm acima da crista (AC); ao nível da crista (AN); 1 mm abaixo da crista sem aposição óssea sobre a plataforma (AB-S); e 1 mm abaixo da crista com aposição óssea sobre a plataforma (AB-C). Os resultados fotoelásticos demonstraram maiores valores de ordem de franja na região apical e menores na região cervical, em todos os modelos, independente do tipo de carga. No MEF verificou-se que o aprofundamento do implante da posição AC para AB-S reduziu progressivamente as tensões de von Mises na região cortical independente do tipo de carga, respectivamente, 0,5595 - 0,3842 Mpa nas cargas cêntricas e 1,5261 - 0,9787 MPa nas excêntricas. Concluiuse que houve redução na concentração de tensões posicionado-se o implante abaixo do crista óssea e uma tendência de aumento de tensão nas amostras AB-C, provavelmente devido à tração do osso existente sobre a plataforma do implante.
Título en inglés
Stress distribution promoted by Morse taper connection implants inserted in different bone levels: photoelastic analysis and finite element method
Palabras clave en inglés
Compressive loads
Dental implant
Finite element analysis
Photoelastic analysis
Resumen en inglés
There is still no consensus on the level that the Morse taper implants should be inserted in relation to the alveolar crestal bone. The literature shows several studies in animals and laboratory implant positioned above, at level or subcrestal. However, different methodologies and techniques make it difficult to define the best level of the implant. This study analyzes qualitatively and quantitatively by using photoelastic analysis and the finite element method (FEM), implants at different levels under static compressive load, to elucidate this issue. Four levels were simulated: 1 mm above the crest (AC); the crest level (AN); 1 mm below the crest free bone apposition on the platform (AB-S); and 1 mm below the crest with bone apposition on the platform (ABC). Photoelastic results demonstrated higher fringe order of values in the apical region and lower in the cervical region, in all models, regardless of the loading type. In MEF found that the deepening of the implant position from AC to AB-S progressively reduced von Mises equivalent stresses in cortical region independent of the load type, respectively, 0.5595 - 0.3842 MPa in centric loads and 1.5261 - 0.9787 MPa in eccentric loads. It was concluded that there was a reduction in stress concentration on the implant positioned below the alveolar crest and a tendency of an increase in tension in the AB-C samples, probably due to traction on the existing bone implant platform.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-06-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.