  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2016.tde-05082016-151221
Document
Auteur
Nom complet
Isabela Rodrigues Teixeira da Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Sesma, Newton (Président)
César Neto, João Batista
Coppedê, Abílio Ricciardi
Romano, Marcelo Munhóes
Titre en portugais
Efeito do parafuso cônico na simulação da mastigação sobre a interface implante/pilar em diferentes relações coroa/implante
Mots-clés en portugais
Implantação Dentária
Prótese Dentária Fixada por Implante
Torque
Resumé en portugais
Este estudo tem como objetivo avaliar 2 diferentes desenhos de parafusos de pilares, o parafuso de cabeça quadrada (PCQ) e o parafuso de cabeça cônica (PCC), verificando se em diferentes relações coroa/implante (RCI) haverá mudança no contra-torque após a ciclagem mecânica. Inicialmente a área superficial do PCQ e do PCC foi mensurada através da análise digital das imagens dos parafusos no software de projeto 3D SolidWorks. Foram utilizados 40 conjuntos Implante/Parafuso/Pilar, os conjuntos foram divididos em 4 grupos: GRUPO A: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCQ; GRUPO B: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCQ; GRUPO C: 10 conjuntos com pilares medindo 9,8mm de altura, simulando uma RCI>1, fixados com PCC e GRUPO D: 10 conjuntos com pilares medindo 6,0mm de altura, simulando uma RCI<1, fixados com PCC. Os 40 conjuntos foram fixados em resina acrílica a uma angulação de 30º em relação ao longo eixo. Os pilares foram fixados aos implantes aplicando um torque de aperto de 35Ncm. Os conjuntos foram posicionados na máquina de ensaios de simulação de mastigação que opera com cargas de 100Ncm e cada grupo foi ciclado até atingir 1.0x106 ciclos. Os contra-torques dos parafusos foram aferidos em torquímetro digital para todos os grupos em 2 momentos (pré-ciclagem mecânica e pós-ciclagem mecânica). Para analisar os resultados a metodologia estatística de ANOVA (nível de significância de p <= 0,05) foi utilizada, seguida de comparações múltiplas de Tukey. Na mensuração da área superficial dos parafusos verificou-se que o PCC apresenta maior área de contato entre a interface pilar/parafuso (4,16 mm²) do que o PCQ (1,76 mm²). Avaliando os fatores testados e os p-valores observou-se que o PCQ é diferente estatisticamente do PCC (p-valor <0,0001), independente do momento de avaliação, sendo que a porcentagem de contra-torque é maior para PCC (90,6%) do que para PCQ (80,9%); a RCI>1 não difere estatisticamente da RCI<1 (p-valor 0,1203), apesar da porcentagem de contra-torque ser menor para RCI>1 (84,6%) do que para RCI<1 (86,8%) e o momento pré-ciclagem mecânica diferente estatisticamente do momento pós-ciclagem mecânica (p-valor <0,0001), sendo que na pré-ciclagem a média de porcentagem do contra-torque é maior (92,5%) do que na pós-ciclagem (78,9%). Baseado nos resultados e dentro das limitações do presente estudo, podemos concluir que o PCC apresenta desempenho superior ao PCQ, no que se diz respeito a afrouxamento, o que caracteriza o PCC como uma possibilidade de melhoria em sistemas de implantes de conexão hexagonal externa. Foi possível concluir também que o desenho cônico do PCC influencia no contra-torque após a ciclagem mecânica, sendo indicado sobretudo em uma situação de RCI>1, onde o parafuso é mais requisitado.
Titre en anglais
Effect of the conical head screw in the mechanical loading on implant/abutment interface in different crown/implant ratio
Mots-clés en anglais
Dental Implantation
Dental Prosthesis
Implant-Supported
Torque
Resumé en anglais
The aims of this study is to evaluate two different abutment screws designs, a flat head screw (FHS) and a conical head screw (CHS), making sure if different crown/implant ratio (CIR) result changes in the removal torque after mechanical cycling. Initially, the surface area of the FHS and a CHS was measured by digital image analysis of the screws in 3D SolidWorks Software. Forty sets implant/screw/abutment were used, the sets were divided into 4 groups: GROUP A: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with FHS; GROUP B: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with FHS; GROUP C: 10 sets with abutments 9,8mm height, simulating a CIR>1, fixed with CHS and GROUP D: 10 sets with abutments 6,0mm height, simulating a CIR<1, fixed with CHS. The sets were fixed in acrylic resin angled 30 ° to the long axis. The abutments were fixed to the implants by applying a torque of 35Ncm. The sets were mechanically loaded. The peak load was 100Ncm vertical force and each group was performed for 1,0x106 cycles. The preload and the postload reverse toque was measured with the digital torque meter and recorded. To analyze the results the methodology of ANOVA (significance level of p <= 0, 05) was used followed by Tukey multiple comparisons. In measuring the surface area of the screws, we found that CHS has greater contact area in the abutment/screw interface (4,16mm²) compared to FHS (1,76mm²). Evaluating the factors tested and p-values we have statistically difference between FHS and CHS (p- value < 0,0001), regardless the time of evaluation, the percentage of CHS reverse torque (90,6 %) is higher than FHS reverse torque (80,9%); CIR>1 and CIR<1 does not differ statistically (p-value 0,1203), although the percentage of reverse torque CIR>1 (84,6 %) is smaller than the percentage of reverse torque CIR<1 (86,8%) and the mechanical preload time differ statistically mechanical postloading time (p-value<0,0001 ), whereas the reversal torque in preload time (92,5%) is largest than reversal torque in postloading time (78,9 %). Based on the results and within the limitations of this study, we can conclude that the CHS outperform the FHS, as regards loosening, which features the CHS as a possible improvement in external-hex implants connections. It was also possible to conclude that the CHS design influences the reverse torque after the mechanical loading, being particularly suitable in a situation CIR>1, where the screw is most required.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-08-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.